多边法三维坐标测量系统常由测量基站、待测目标和数据处理环节组成。
多边法是通过多个测量基站对同一待测目标进行测量获得基站与待测点间的距离,使用距离公式组成方程组,求解方程组达到对三维坐标进行解算的目的。测站之间的相对位置需要已知,即完成自标定,才能利用方程组计算空间坐标,因而需要找到方便、高精度的自标定方法。
-
自标定的目的是要得到测站间的位置关系,具体来说是测站的测量原点之间的位置关系,若能直接测得各测站测量原点之间的距离,就可以不通过测量目标点也达到自标定的目的。
如图1所示,自标定时按照第一测站在原点,第二测站在
$x$ 轴上,第三测站在$xoy$ 平面内,其余测站在空间随意分布的方式建系。由于多边法测量三维坐标至少需要三站,而多边系统通常使用四站组建,因而在无目标点自标定方案下,可以构建四站模型与三站模型,四站模型在合肥工业大学的相关研究中已经提及[13],文中将列出三站模型的推导。
三站自标定解算按如下方程组进行:
$$ \left\{ \begin{array}{l} {x_1} = {y_1} = {z_1} = {y_2} = {z_2} = {z_3} = 0 \\ {x_2}^2 = {d_{21}}^2 \\ {x_3}^2 + {y_3}^2 = {d_{31}}^2 \\ {({x_3} - {x_2})^2} + {y_3}^2 = {d_{32}}^2 \end{array} \right. $$ (1) 第i站的坐标为
$\left( {{x_i},{y_i},{z_i}} \right)$ ,i=1,2,3。该方程可以直接求解得到公式(2):
$$\left\{ \begin{array}{l} {x_2} = \pm {d_{21}} \\ {x_3} = \dfrac{{{d_{32}}^2 - {d_{31}}^2 - {x_2}^2}}{{ - 2{x_2}}} \\ {y_3} = \pm \sqrt {{d_{31}}^2 - {x_3}^2} \end{array} \right.$$ (2) 正负值根据实际测量环境确定,得到自标定结果即三测站的坐标分别
$(0,0,0),({x_2},0,0),({x_3},{y_3},0)$ 。 -
为验证文中方法的可行性与有效性,利用该方法进行了自标定实验和测量精度验证实验,并对误差进行了分析。
-
根据前文介绍的系统构建方式,采用LEICA AT403激光跟踪仪作为“原点跟踪仪”,采用LEICA AT960激光跟踪仪作为“移站跟踪仪”,两种型号的跟踪仪具有相同的标称测距精度和点位测量精度,将夹具固定在LEICA AT960的测头上连接靶座与靶球,如图5所示。
由“原点跟踪仪”分别对三个位置的“移站跟踪仪”上挂载的靶球坐标进行连续测量,得到三组点云,对该三组点云分别进行球心拟合,拟合时将公差设置为0.02 mm,拟合情况如图5所示,拟合结果如表1所示。
表 1 球心拟合数据及结果
Table 1. Spherical center fitting data and result
Position Position 1 Position 2 Position 3 Number of points 1 000 1 000 1 000 Common difference/mm 0.020 0.020 0.020 Number of effective point 646 617 469 Spherical center coordinate/mm X Y Z X Y Z X Y Z –2 212.401 –952.396 –29.726 –3 132.017 –1 866.354 –33.046 –4 084.727 –4 692.426 –151.759 Radius/mm 134.669 134.662 134.526 由拟合得到的球心坐标计算得到两台四站跟踪仪间的距离分别为
${d_{21}} = {\rm{2\;408}}{\rm{.871\;mm}}$ ,${d_{{\rm{3}}1}} = {\rm{3\;646}}{\rm{.080\;mm}}$ ,${d_{{\rm{4}}1}} = {\rm{6\;223}}{\rm{.093\;mm}}$ ,${d_{{\rm{32}}}} = {\rm{1\;296}}{\rm{.543\;mm}}$ ,${d_{{\rm{42}}}} = {\rm{4\;184}}{\rm{.295\;mm}}$ ,${d_{{\rm{43}}}} = {\rm{2\;984}}{\rm{.700\;mm}}$ ,将该组数值代入到四站无目标点自标定模型完成自标定,结果为${x_2} = {\rm{2\;408}}{\rm{.871}}$ ,${x_{\rm{3}}} = {\rm{3\;614}}{\rm{.875}}$ ,${x_{\rm{4}}} = {\rm{5\;608}}{\rm{.691}}$ ,${y_{\rm{3}}} = {\rm{476}}{\rm{.022}}$ ,${y_{\rm{4}}} = {\rm{2\;692}}{\rm{.132}}$ ,${z_{\rm{4}}} = - {\rm{147}}{\rm{.995}}$ 。 -
在得到测站间相对位置即完成自标定后,通过对空间中一定长度的标准尺两端距离进行测量来验证系统的测量精度。实验中使用标称长度1 000.943 mm的标准尺,如图6所示。将标准尺放置在距“原点跟踪仪”约20 m的位置上,使用“原点跟踪仪”对标准尺两端点进行测量,使用“移站跟踪仪”在位置1、位置2、位置3分别对标准尺两端点进行测量,得到标准尺两端点的三维坐标。被测标准尺如图7所示。
按照多边法原理解算得到端点坐标,再根据距离公式得到标准尺的长度。另外通过保存的激光跟踪仪笛卡尔坐标,可以得到三站跟踪仪每一站测得的包含角度误差影响的标准尺长度。两者的数据及比较如表2所示。
表 2 四站模型多边法与单站测得标准尺长度比较
Table 2. Comparison of scale bar length measured by four-station multilateral method and single station
Point 1 Point 2 Length /mm Absolute value of
difference/μmX/mm Y/mm Z/mm X/mm Y/mm Z/mm Original point tracker –15 546.039 –15 248.192 –649.910 –14 824.764 –15 942.233 –659.255 1 001.008 65 Moving station tracker 1 17 834.335 –7 998.228 –672.218 18 258.769 –7 091.881 –664.588 1 000.833 110 Moving station tracker 2 –1 628.084 –18 162.704 –1 013.202 –633.001 –18 269.683 –1 029.440 1 000.949 6 Moving station tracker 3 –9 217.2173 –12 558.486 –580.287 –8 375.950 –13 100.796 –594.329 1 001.013 70 Multilateral 20 315.755 7 843.199 –586.987 19 928.030 8 764.959 –630.0941 1 000.915 28 两种型号的激光跟踪仪标称点位误差均为±(15 μm+6 μm)/m,则在20 m的距离上,标称点位误差约为135 μm。标准尺标称长度为1000.943 mm,由数据处理得到的四站单台激光跟踪仪对标准尺长度的测量误差绝对值分别为65 μm,110 μm,6 μm,70 μm,平均值为62.75 μm,而由多边法计算得到的标准尺长度误差绝对值为28 μm。
-
除四站模型外,也可以构建三站模型,在文中所述系统构建方案的基础上减掉一站,得到三站系统,用相似的方式对三站系统的性能进行验证,由于可预见的三站系统相对于四站系统的性能下降,验证三站系统时在约7.5 m的距离上放置标称长度为969.045 mm的标准尺,得到结果如表3所示。
表 3 三站模型多边法与单站测得标准尺长度比较
Table 3. Comparison of scale bar length measured by three-station multilateral method and single station
Point 1 Point 2 Length/mm Absolute value of
difference/μmX/mm Y/mm Z/mm X/mm Y/mm Z/mm Original point tracker 4 869.88 5 909.79 –451.91 5 284.89 5 034.15 –439.30 969.164 119 Moving station tracker 1 4 869.82 5 909.84 –452.02 5 284.76 5 034.17 –439.39 969.095 50 Moving station tracker 2 4 869.77 5 909.93 –452.01 5 284.81 5 034.32 –439.41 969.076 31 Multilateral 5 507.68 –5 324.49 –400.97 4 601.88 –5 668.67 –393.14 969.024 21 在7.5 m距离上的跟踪仪标称点位误差为60 μm,三单站对标称969.045 mm标准尺长度进行测量时的长度误差为119 μm,50 μm,31 μm,平均值为67 μm,而由三站系统按多边法结算得到的标准尺误差为21 μm。
-
如前文设想,通过人工在自标定结果坐标的X,Y,Z三个方向上添加“误差”并观察结果的改变,若结果变化有限,则可证明该方案的主要误差对测量结果影响较小。
现对四站模型的自标定结果添加误差,在X,Y方向上分别添加±10 ~ ±60 μm的误差,在Z方向上添加±10 ~ ±100 μm的误差,为观察各方向误差影响的严重程度,同时在测站的距离测量结果上添加误差,得到同等大小的测距误差造成的测量结果变化。得到的测量结果与不添加误差时的测量结果的差的绝对值如图8所示,其中图8(a)为添加正向误差时的结果,图8(b)为添加负向误差时的结果。
可知X,Y方向上误差引起的结果改变相对较为明显,但也与相同大小的测距误差引起的结果改变相当。而如上文分析,文中方案中主要误差方向Z方向上的误差引起的结果改变很小,在添加+100 μm误差时,测量结果改变最大只有3 μm,添加–100 μm误差时,测量结果改变只有6 μm,可认为Z方向上的误差对测量结果几乎无影响。进而得到结论,在测头上挂载重量引入的误差,Z方向对测量结果几乎不产生影响,而X,Y方向的误差自身很小,即使产生影响也与跟踪仪本身的测距误差的影响量级相当,可证明文中方案可行。
Multilateral laser tracking system self-calibration method based on spherical center fitting
-
摘要: 随着大尺寸工件和设备的制造加工以及装配的精度要求提高,对工件加工装配过程进行测量的测量系统精度要求也有所提高。多边法激光跟踪三维坐标测量系统只利用距离测量数据解算空间点坐标,能够避免激光跟踪仪角度测量带来的误差。文中提出了一种通过在跟踪仪测头挂载夹具进行球心拟合来获取跟踪仪测量原点的方式进行系统自标定,并辅以移站的方式,可使用两台激光跟踪仪构建四站多边法激光跟踪三维坐标测量系统。另外,文中还尝试了三站系统的构建。实验证明,四站系统将对标称长度1000.943 mm位于约20 m处的标准尺长度测量误差由最大110 μm减小至28 μm,三站系统将对标称长度969.045 mm位于约7.5 m处的标准尺长度的测量误差由最大67 μm减小至21 μm,相较于单台跟踪仪提高了精度,相较于传统多边系统降低了测站数量和成本,能够在工业现场实现高精度三维坐标测量。Abstract: With the increase of precision requirements for manufacturing, processing and assembly of large scale workpieces and equipment, high precision measurement system is needed to measure the machining and assembling process of workpiece. Multilateral laser tracking 3D coordinate measuring system measures the distance data to solve the space point coordinates which can avoid the error caused by the angle measurement of laser tracker. Based on non-target self-calibration model, a spherical center fitting-self-calibration method for multilateral laser tracking 3D coordinate measuring system was constructed in this paper. By mounting an fixture to the laser tracker and moving station, a four station laser tracking 3D coordinate measuring system can be constructed. In addition, a three station system was also constructed. The experimental results show that the error of distance between the two ends of the scale bar with nominal length 1000.943 mm measured by three-station system is reduced from 110 μm to 28 μm at the distance of 20 m, and the distance error between the two ends of the scale bar with nominal length of 969.045 mm measured by four-station system is reduced from 67 μm to 21 μm at the distance of 7.5 m. Compared with single-tracker measurement, the precision is improved, the number of station and the cost for the system are reduced compared with traditional multilateral measurement system. The system can realize high precision for 3D coordinate measurement in industrial field.
-
表 1 球心拟合数据及结果
Table 1. Spherical center fitting data and result
Position Position 1 Position 2 Position 3 Number of points 1 000 1 000 1 000 Common difference/mm 0.020 0.020 0.020 Number of effective point 646 617 469 Spherical center coordinate/mm X Y Z X Y Z X Y Z –2 212.401 –952.396 –29.726 –3 132.017 –1 866.354 –33.046 –4 084.727 –4 692.426 –151.759 Radius/mm 134.669 134.662 134.526 表 2 四站模型多边法与单站测得标准尺长度比较
Table 2. Comparison of scale bar length measured by four-station multilateral method and single station
Point 1 Point 2 Length /mm Absolute value of
difference/μmX/mm Y/mm Z/mm X/mm Y/mm Z/mm Original point tracker –15 546.039 –15 248.192 –649.910 –14 824.764 –15 942.233 –659.255 1 001.008 65 Moving station tracker 1 17 834.335 –7 998.228 –672.218 18 258.769 –7 091.881 –664.588 1 000.833 110 Moving station tracker 2 –1 628.084 –18 162.704 –1 013.202 –633.001 –18 269.683 –1 029.440 1 000.949 6 Moving station tracker 3 –9 217.2173 –12 558.486 –580.287 –8 375.950 –13 100.796 –594.329 1 001.013 70 Multilateral 20 315.755 7 843.199 –586.987 19 928.030 8 764.959 –630.0941 1 000.915 28 表 3 三站模型多边法与单站测得标准尺长度比较
Table 3. Comparison of scale bar length measured by three-station multilateral method and single station
Point 1 Point 2 Length/mm Absolute value of
difference/μmX/mm Y/mm Z/mm X/mm Y/mm Z/mm Original point tracker 4 869.88 5 909.79 –451.91 5 284.89 5 034.15 –439.30 969.164 119 Moving station tracker 1 4 869.82 5 909.84 –452.02 5 284.76 5 034.17 –439.39 969.095 50 Moving station tracker 2 4 869.77 5 909.93 –452.01 5 284.81 5 034.32 –439.41 969.076 31 Multilateral 5 507.68 –5 324.49 –400.97 4 601.88 –5 668.67 –393.14 969.024 21 -
[1] Ye Shenghua, Zhu Jigui, Zhang Zili, et al. Status and development of large-scale coordinate measurement research [J]. Acta Metrologica Sinica, 2008, 29(z1): 1-6. (in Chinese) [2] Lin Jiarui, Zhu Jigui, Zhang Haolin, et al. Field evaluation of laser tracker angle measurement erro [J]. Chinese Journal of Scientific Instrument, 2012, 33(2): 464-468. (in Chinese) [3] Wu Bin, Xu You, Yang Fengting, et al. 3D coordinate measuring system based on laser tracking absolute length measurement multilateral method [J]. Infrared and Laser Engineering, 2018, 47(8): 0806007. (in Chinese) [4] Toshiyuki Takatsuji, Mitsuo Goto, Tomizo Kurosawa, et al. The first measurement of a three-dimensional coordinate by use of a laser tracking interferometer system based on trilateration [J]. Measurement Science & Technology, 1998, 9(1): 38-41. [5] Toshiyuki Takatsuji, Yoshihiko Koseki, Mitsuo Goto, et al. Restriction on the arrangement of laser trackers in laser trilateration [J]. Measurement Science & Technology, 1998, 9(8): 1357-1359. [6] Lin Yongbing, Zhang Guoxiong, Li Xinhua, et al. Four-beam laser tracking interferometer system for three-dimensional coordinate measurement [J]. Acta Optica Sinica, 2003, 23(9): 1030-1036. (in Chinese) doi: 10.3321/j.issn:0253-2239.2003.09.002 [7] Lin Yongbing, Zhang Guoxiong, Li Zhen, et al. Self-calibration and simulation of the four-beam laser tracking interferometer system for 3D coordinate measurement [J]. Chinese Journal of Scientific Instrument, 2003, 24(2): 205-210. (in Chinese) doi: 10.3321/j.issn:0254-3087.2003.02.026 [8] Lin Yongbing, Zhang Guoxiong, Li Zhen, et al. Optimal arrangement of four-beam laser tracking system for 3D coordinate measurement [J]. Chinese Journal of Lasers, 2002, 29(11): 1000-1005. (in Chinese) doi: 10.3321/j.issn:0258-7025.2002.11.011 [9] Hu Jinzhong, Yu Xiaofen, Peng Peng, et al. Layout optimization of three-dimensional coordinate measurement system based on laser multi-lateration [J]. Chinese Journal of Lasers, 2014, 41(1): 0108006. (in Chinese) doi: 10.3788/CJL201441.0108006 [10] Hu Jinzhong, Yu Xiaofen, Ren Xing, et al. Optimal layout of three-dimensional coordinate measurement system based on laser multi-lateration [J]. Chinese Journal of Lasers, 2014, 41(7): 0708001. (in Chinese) doi: 10.3788/CJL201441.0708001 [11] Fan Baixing, Li Guangyun, Li Peizhen, et al. Adjustment of a laser interferometer 3D rank-defect free-network [J]. Geomatics and Information Science of Wuhan University, 2015, 40(2): 222-226. (in Chinese) [12] Wang Luogang, Wang Tonghe, Fan Baixing. Application of Levenberg-Marquardt algorithm to 3D trilateration network [J]. Engineer of Surveying and Mapping, 2016, 25(3): 68-72. (in Chinese) doi: 10.3969/j.issn.1006-7949.2016.03.015 [13] Hu Jinzhong, Yu Xiaofen, Liu Yuanyuan, et al. Research of self-calibration of 3D coordinate measurement system based on laser multi-lateration [J]. Journal of Electronic Measurement and Instrumentation, 2014, 28(2): 130-137. (in Chinese)