留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

柔性复合基体光纤布拉格光栅曲率传感器

张雄雄 宋言明 孙广开 孟凡勇 董明利

张雄雄, 宋言明, 孙广开, 孟凡勇, 董明利. 柔性复合基体光纤布拉格光栅曲率传感器[J]. 红外与激光工程, 2019, 48(2): 222001-0222001(7). doi: 10.3788/IRLA201948.0222001
引用本文: 张雄雄, 宋言明, 孙广开, 孟凡勇, 董明利. 柔性复合基体光纤布拉格光栅曲率传感器[J]. 红外与激光工程, 2019, 48(2): 222001-0222001(7). doi: 10.3788/IRLA201948.0222001
Zhang Xiongxiong, Song Yanming, Sun Guangkai, Meng Fanyong, Dong Mingli. Fiber Bragg grating curvature sensor based on flexible composite matrix[J]. Infrared and Laser Engineering, 2019, 48(2): 222001-0222001(7). doi: 10.3788/IRLA201948.0222001
Citation: Zhang Xiongxiong, Song Yanming, Sun Guangkai, Meng Fanyong, Dong Mingli. Fiber Bragg grating curvature sensor based on flexible composite matrix[J]. Infrared and Laser Engineering, 2019, 48(2): 222001-0222001(7). doi: 10.3788/IRLA201948.0222001

柔性复合基体光纤布拉格光栅曲率传感器

doi: 10.3788/IRLA201948.0222001
基金项目: 

教育部"长江学者与创新团队发展计划"(IRT_16R07);北京市属高等学校高层次人才引进与培养计划(IDHT20170510)

详细信息
    作者简介:

    张雄雄(1992-),男,硕士生,主要从事光纤传感技术等方面的研究。Email:xiongxiong_z@sina.cn

  • 中图分类号: TP212;TN253

Fiber Bragg grating curvature sensor based on flexible composite matrix

  • 摘要: 面向生物医学智能装备和软体机器人等领域柔性机构以及高端装备和重大基础设施复杂结构的曲率测量需求,提出一种高适应性柔性曲率传感器。通过将光纤布拉格光栅封装在硅胶基体中,并将硅胶基体与聚氯乙烯薄片贴合,形成基于光纤布拉格光栅的柔性硅胶曲率传感器。采用光纤传感解调系统和标准曲率标定块,实验测得光纤光栅传感器反射谱特征及其随标定块曲率变化规律,分析了光栅波长位移与曲率变化的关系以及传感器灵敏度与嵌入硅胶基体深度的关系。实验结果表明:硅胶-聚氯乙烯基体的曲率传感器可以实现曲率变化实时测量,最高灵敏度可达0.329 2 nm/m-1。随着光纤光栅嵌入深度的增加,传感器灵敏度在0.2~0.35 nm/m-1范围内逐渐增大。在多次重复测量中传感器具有较好的一致性,可用于柔性机构和复杂结构的曲率测量。
  • [1] Majidi C, Kramer R, Wood R J. A non-differential elastomer curvature sensor for softer-than-skin electronics[J]. Smart Materials Structures, 2011, 20(10):105017.
    [2] Song S, Li Z, Yu H, et al. Electromagnetic positioning for tip tracking and shape sensing of flexible robots[J]. IEEE Sensors Journal, 2015, 15(8):4565-4575.
    [3] Asbeck A T, Rossi S M M D, Galiana I, et al. Stronger, smarter, softer:next-generation wearable robots[J]. IEEE Robotics Automation Magazine, 2014, 21(4):22-33.
    [4] Abayazid M, Kemp M, Misra S. 3D flexible needle steering in soft-tissue phantoms using Fiber Bragg Grating sensors[C]//IEEE International Conference on Robotics and Automation. IEEE, 2013:5843-5849.
    [5] Lou Xiaoping, Chen Zhongqin, Zhuang Wei, et al. Error analysis and calibration for FBG shape reconstruction based on non-orthogonal curvatures[J]. Chinese Journal of Scientific Instrument, 2017, 38(2):386-393. (in Chinese)
    [6] Roesthuis R J, Kemp M, Dobbelsteen J J V D, et al. Three-dimensional needle shape reconstruction using an array of fiber Bragg grating sensors[J]. IEEE/ASME Transactions on Mechatronics, 2014, 19(4):1115-1126.
    [7] Yang Linghui, Wang Lijun, Lin Jiarui, et al. 3D coordinate measurement method based on space resection of the orthogonal cylindrical imaging camera[J]. Infrared and Laser Engineering, 2018, 47(3):0317001. (in Chinese)
    [8] Zhao Yalong, Liu Shouqi, Zhang Qican. 3D shape measurement accelerated by GPU[J]. Infrared and Laser Engineering, 2018, 47(3):0317003. (in Chinese)
    [9] Xu Ning, Dai Ming. Design of distributed optical fiber sensor for temperature and pressure measurement[J]. Chinese Optics, 2015, 8(4):629-635. (in Chinese)
    [10] Xu Guoquan, Xiong Daiyu. Applications of fiber Bragg grating sensing technology in engineering[J]. Chinese Optics, 2013, 6(3):306-317. (in Chinese)
    [11] Arritt B J, Klimcak C, Pollard E, et al. Shape determination of large deployable space structures through the use of fiber-optics with integrated fiber-Bragg's gratings[C]//SPIE, 2007, 6530:653016.
    [12] Payo I, Feliu V, Cortzar O D. Fibre Bragg grating (FBG) sensor system for highly flexible single-link robots[J]. Sensors Actuators A Physical, 2009, 150(1):24-39.
    [13] Bang H J, Kim H I, Lee K S. Measurement of strain and bending deflection of a wind turbine tower using arrayed FBG sensors[J]. International Journal of Precision Engineering and Manufacturing, 2012, 13(12):2121-2126.
    [14] Di Haiting, Fu Yili. Three dimensional reconstruction of curved shape based on curvature fiber optic sensor[J]. Optics and Precision Engineering, 2010, 18(5):1092-1098. (in Chinese)
    [15] Zhang Yanan, Xiao Hai, Shen Linyong, et al. Coordinate point fitting in FBG curve reconstruction algorithm[J]. Optics and Precision Engineering, 2016, 24(9):2149-2157. (in Chinese)
    [16] Shin W, Lee Y L, Yu B A, et al. Highly sensitive strain and bending sensor based on in-line fiber Mach-Zehnder interferometer in solid core large mode area photonic crystal fiber[J]. Optics Communications, 2010, 283(10):2097-2101.
    [17] Martinezrios A, Monzonhernandez D, Salcedadelgado G, et al. Compact optical fiber curvature sensor based on concatenating two tapers[J]. Optics Letters, 2011, 36(22):4380-4382.
    [18] Ge J, James A E, Xu L, et al. Bidirectional soft silicone curvature sensor based on off-centered embedded fiber Bragg grating[J]. IEEE Photonics Technology Letters, 2016, 28(20):2237-2240.
    [19] Wang H, Zhang R, Chen W, et al. Shape detection algorithm for soft manipulator based on fiber bragg gratings[J]. IEEE/ASME Transactions on Mechatronics, 2016, 21(6):2977-2981.
    [20] Payo I, Feliu V, Cortazar O D. Fibre Bragg grating (FBG) sensor system for highly flexible single-link robots[J].Sensors and Actuators A:Physical, 2009, 150:24-39.
  • [1] 唐翔, 吴俊, 黎琪慧, 辛璟焘, 董明利.  基于FBG的微小型三轴振动传感器研究 . 红外与激光工程, 2024, 53(2): 20230518-1-20230518-9. doi: 10.3788/IRLA20230518
    [2] 王彦, 程东升, 蒋超, 葛子阳, 金萍.  基于FBG柔性传感器的滑觉信号特性识别 . 红外与激光工程, 2023, 52(3): 20220587-1-20220587-11. doi: 10.3788/IRLA20220587
    [3] 陆锋, 陈亮, 张俊生.  级联光栅硅胶封装的脉象传感器研究 . 红外与激光工程, 2023, 52(2): 20220324-1-20220324-8. doi: 10.3788/IRLA20220324
    [4] 郑晨, 冯文林, 何思杰, 李邦兴.  用于测量折射率的光纤迈克尔逊干涉型传感器 . 红外与激光工程, 2022, 51(5): 20210327-1-20210327-5. doi: 10.3788/IRLA20210327
    [5] 丁磊, 余烈, 谢勤岚, 朱兰艳.  光纤马赫曾德尔干涉曲率传感器的膝关节曲率检测系统研究 . 红外与激光工程, 2021, 50(12): 20210195-1-20210195-9. doi: 10.3788/IRLA20210195
    [6] 刘晓利, 何懂, 陈海龙, 蔡泽伟, 殷永凯, 彭翔.  结构光三维传感器测量网相关技术 . 红外与激光工程, 2020, 49(3): 0303007-0303007-10. doi: 10.3378/IRLA202049.0303007
    [7] 张雄雄, 宋言明, 孟凡勇, 孙广开, 祝连庆.  变体飞行器柔性复合蒙皮植入式光纤形状传感 . 红外与激光工程, 2019, 48(6): 622003-0622003(8). doi: 10.3788/IRLA201948.0622003
    [8] 郭伟, 董丽虹, 王海斗, 马润波, 向明, 徐滨士.  喷涂层下基体中裂纹缺陷的超声红外识别方法 . 红外与激光工程, 2018, 47(S1): 36-43. doi: 10.3788/IRLA201847.S104001
    [9] 岳威, 韩隆, 张阔, 韩永昶, 赵明艳.  氧化铝基体3.7 μm与4.8 μm双波段带通滤光膜研制 . 红外与激光工程, 2018, 47(6): 621001-0621001(6). doi: 10.3788/IRLA201847.0621001
    [10] 邹媛媛, 李鹏飞, 左克铸.  三线结构光视觉传感器现场标定方法 . 红外与激光工程, 2018, 47(6): 617002-0617002(6). doi: 10.3788/IRLA201847.0617002
    [11] 冯婕, 李豫东, 文林, 郭旗.  CMOS传感器辐射损伤对视觉位姿测量系统性能的影响机制 . 红外与激光工程, 2017, 46(S1): 69-73. doi: 10.3788/IRLA201746.S117002
    [12] 李红, 祝连庆, 张钰民, 刘锋, 骆飞, 黄强先.  线阵InGaAs扫描FBG反射谱的传感解调方法 . 红外与激光工程, 2016, 45(1): 122004-0122004(5). doi: 10.3788/IRLA201645.0122004
    [13] 范宜艳, 赵斌.  基于姿态角传感器与旋转测距仪的坐标测量 . 红外与激光工程, 2016, 45(1): 117001-0117001(5). doi: 10.3788/IRLA201645.0117001
    [14] 郑妍, 邢砾云, 常天英, 王敏, 孙玉锋, 崔洪亮, 刘野, 赵越.  光纤SPR传感器的信号检测及处理 . 红外与激光工程, 2015, 44(6): 1865-1871.
    [15] 武超群, 李梅, 周璐春.  哈特曼传感器仿真平台设计 . 红外与激光工程, 2015, 44(2): 567-571.
    [16] 吴飞, 董杰, 田海霞, 蔡璐璐.  黑体腔高温传感器结构设计 . 红外与激光工程, 2015, 44(9): 2609-2614.
    [17] 沈小燕, 张良岳, 孙杰, 胡佳成, 李东升.  改进剥层法实现FBG非均匀应变传感解调 . 红外与激光工程, 2015, 44(12): 3734-3739.
    [18] 关祥毅, 赵丽丽, 朱琳, 郑大宇, 孙剑明.  光纤传感器在带传动参数测量中的应用 . 红外与激光工程, 2013, 42(11): 3127-3131.
    [19] 王广宇, 洪延姬, 潘虎, 宋俊玲.  可调谐半导体激光吸收传感器的温度测量验证 . 红外与激光工程, 2013, 42(9): 2358-2363.
    [20] 龚华平, 杨效, 屠于梦, 宋海峰, 董新永.  FBG传感器和电阻应变仪的振动监测特性 . 红外与激光工程, 2013, 42(3): 810-813.
  • 加载中
计量
  • 文章访问数:  480
  • HTML全文浏览量:  87
  • PDF下载量:  55
  • 被引次数: 0
出版历程
  • 收稿日期:  2018-09-05
  • 修回日期:  2018-10-03
  • 刊出日期:  2019-02-25

柔性复合基体光纤布拉格光栅曲率传感器

doi: 10.3788/IRLA201948.0222001
    作者简介:

    张雄雄(1992-),男,硕士生,主要从事光纤传感技术等方面的研究。Email:xiongxiong_z@sina.cn

基金项目:

教育部"长江学者与创新团队发展计划"(IRT_16R07);北京市属高等学校高层次人才引进与培养计划(IDHT20170510)

  • 中图分类号: TP212;TN253

摘要: 面向生物医学智能装备和软体机器人等领域柔性机构以及高端装备和重大基础设施复杂结构的曲率测量需求,提出一种高适应性柔性曲率传感器。通过将光纤布拉格光栅封装在硅胶基体中,并将硅胶基体与聚氯乙烯薄片贴合,形成基于光纤布拉格光栅的柔性硅胶曲率传感器。采用光纤传感解调系统和标准曲率标定块,实验测得光纤光栅传感器反射谱特征及其随标定块曲率变化规律,分析了光栅波长位移与曲率变化的关系以及传感器灵敏度与嵌入硅胶基体深度的关系。实验结果表明:硅胶-聚氯乙烯基体的曲率传感器可以实现曲率变化实时测量,最高灵敏度可达0.329 2 nm/m-1。随着光纤光栅嵌入深度的增加,传感器灵敏度在0.2~0.35 nm/m-1范围内逐渐增大。在多次重复测量中传感器具有较好的一致性,可用于柔性机构和复杂结构的曲率测量。

English Abstract

参考文献 (20)

目录

    /

    返回文章
    返回