[1] Zhang Yu, Yang Changcheng, Yang Kuntao. Design on athermal infrared diffractive/refractive hybrid optical system in 8-14 m[J]. Acta Optica Sinica, 2005, 25(11): 1535-1538. (in Chinese) 张羽, 杨长城, 杨坤涛. 8~14 m波段折衍射混合红外光学系统的热补偿设计[J]. 光学学报, 2005, 25(11): 1535-1538.
[2]
[3] Chen Xiao, Yang Jianfeng, Ma Xiaolong, et al. Athermalization design of wide temperature range for hybrid refractive/diffractive infrared objective[J]. Infrared and Laser Engineering, 2011, 40(1): 79-82. (in Chinese) 陈潇, 杨建峰, 马小龙, 等. 折/衍混合红外物镜超宽温度消热差设计[J]. 红外与激光工程, 2011, 40(1): 79-82.
[4]
[5]
[6] Bai Yu, Yang Jianfeng, Ma Xiaolong, et al. Athermalization of long-wavelength infrared optical system[J]. Infrared Technology, 2008, 30(10): 583-585. (in Chinese) 白榆,杨建峰,马小龙, 等. 长波红外光学系统无热化设计[J]. 红外技术, 2008, 30(10): 583-585.
[7]
[8] Xi Xiao, Li Xiaotong, Cen Zhaofeng. Passive athermalized infrared optical system design[J]. Optical Instruments, 2005, 27(1): 42-46. (in Chinese) 奚晓, 李晓彤, 岑兆丰. 被动式红外光学系统无热设计[J]. 光学仪器, 2005, 27(1): 42-46.
[9]
[10] Song Yanfeng, Shao Xiaopeng, Xu Jun. Design of a hybrid infrared apochromatic optical system beyond normal temperature[J]. Acta Physica Sinica, 2008, 57(10): 6298-6303. (in Chinese) 宋岩峰, 邵晓鹏, 徐军. 实现复消色差的超常温混合红外光学系统[J]. 物理学报, 2008, 57(10): 6298-6303.
[11]
[12] Sun Jinxia, Liu Jianzhuo, Sun Qiang, et al. Athermal design for hybrid refractive/diffractive conformal optical system[J]. Optics and Precision Engineering, 2010, 18(4): 792-797. (in Chinese) 孙金霞, 刘建卓, 孙强, 等. 折/衍射混合消热差共形光学系统的设计[J]. 光学 精密工程, 2010, 18(4): 792-797.
[13] Qu Hemeng, Zhang Xin, Wang Lingjie, et al. Design of a low F-number compact athermalizing infrared optical system[J]. Acta Optica Sinica, 2012, 32(3): 0322003-1-8. (in Chinese) 曲贺盟, 张新, 王灵杰, 等. 大相对孔径紧凑型无热化红外光学系统设计[J]. 光学学报, 2012, 32(3): 0322003-1-8.
[14]
[15] Li Xiaoyan, Zhong Boliang. Optical design of telephoto lens with inner focusing[J]. Optical Technique, 2002, 28(4): 299-301. (in Chinese) 李晓艳, 钟伯亮. 内调焦摄远镜头的光学设计[J]. 光学技术, 2002, 28(4): 299-301.
[16]
[17]
[18] Liu Yingying, Pang Bo, Du Yunan, et al. Optical design of athermalized infrared telephoto objective lens[J]. Semiconductor Optoelectronics, 2013, 34(5): 858-862. (in Chinese) 刘莹莹, 庞博, 杜玉楠, 等. 红外无热化摄远物镜设计[J]. 半导体光电, 2013, 34(5): 858-862.
[19] Yasuhisa Tamagawa. Dual-band optical systems with a projective athermal chart: design[J]. Appl Opt, 1997, 36(1): 297-301.
[20]
[21]
[22] Tadeusz Kryszczynski. Material problem in athermalization of optical systems[J]. Opt Eng, 1997, 36(6): 1596-1601.
[23] Chen Xiao, Yang Jianfeng, Ma Xiaolong, et al. Athermalization design of wide temperature range for hybrid refractive-diffractive objective in 8-12 m[J]. Acta Optica Sinica, 2010, 30(7): 2089-2092. (in Chinese) 陈潇, 杨建峰, 马小龙, 等. 8~12 m折-衍混合物镜超宽温度消热差设计[J]. 光学学报, 2010, 30(7): 2089-2092.
[24]
[25]
[26] Rogers P J. Athermalized FLIR optics[C]//SPIE, 1990, 1354: 742-751.
[27]
[28] Li Shenghui, Yang Changcheng. Athermal design for infrared hybrid refractive/diffractive optical system[J]. Optics Optoelectronic Technology, 2006, 4(4): 1-3. (in Chinese) 李升辉, 杨长城. 折/衍混合红外光学系统的消热差设计[J]. 光学与光电技术, 2006, 4(4): 1-3.
[29] Song Yanfeng. Design of modern infrared optical system[D]. Xi'an: Xi'an University of Electronic Science and Technology, 2008: 11-12. (in Chinese) 宋岩峰. 现代光学系统设计[D]. 西安: 西安电子科技大学, 2008: 11-12.
[30]
[31] Zhang Xin, Jia Hongguang, Zhang Yue. Optical design of athermalized infrared telepgoto objective[J]. Infrared and Laser Engineering, 2012, 41(1): 178-183. (in Chinese) 张鑫,贾宏光,张跃. 远距型红外消热差物镜设计[J]. 红外与激光工程, 2012, 41(1): 178-183.