[1] Liu Ninglin. Research on mid-infrared mull-er matrix spectroscopic ellipsometer[D]. Huazhong: Huazhong University of Science and Technology, 2019. (in Chinese)
[2] Wu Suyong, Long Xingwu, Yang Kaiyong. An error processing technique for ellipsometry measurement system which minimizes the error of optical parameter characterization of thin films [J]. Acta Optica Sinica, 2012, 32(6): 280. (in Chinese)
[3] Fan Zhentao. Research on the advanced parameters problem of muller matrix ellipsometry system[D]. Beijing: University of Chinese Academy of Sciences , 2019. (in Chinese)
[4] Li W, Zhang C, Jiang H, et al. Depolarization artifacts in dual rotating compensator Mueller matrix ellipsometry [J]. Journal of Optics, 2016, 18(5): 055701. doi:  10.1088/2040-8978/18/5/055701
[5] Liu S Y, Chen X G, Zhang C W. Development of a broadband Mueller matrix ellipsometer as a powerful tool for nano structure metrology [J]. Thin Solid Films, 2015, 584(1): 176-185.
[6] Dai Lina, Deng Jianxun, Wang Juan, et al. The optical constants and Euler angles of anisotropic thin films were studied by using a single wavelength ellipsometer [J]. Journal of South China Normal University (Natural Science Edition), 2019, 51(4): 14-20. (in Chinese)
[7] Zhen Tang. Mul-tipoint calibration method based on stok-es ellipsometry measurement system [J]. Chinese Journal of Lasers, 2012, 39(11): 163-167. (in Chinese)
[8] Urban F K I, Barton D. Numerical ellipsometry: Use of parameter sensitivity to guide measurement selection for transparent anisotropic films [J]. Thin Solid Films, 2018, 663(10): 116-125.
[9] Meng Fanxue. A hybrid algorithm for solving nonlinear least squares problems[D]. Shanghai: Shanghai Jiao Tong University, 2011. (in Chinese)
[10] Yang Liu, Chen Yanping. A new globally con-vergent levenberg-marquardt method for sovling nonlinear system of equations [J]. Mathematica Numerica Sinica, 2008, 30(4): 388-396. (in Chinese)
[11] Zhang Ruizhi, Luo Jinsheng, Chen Minlin. Calibr-ation method for azimuth angle of a rotary polarizer-type automatic ellipsometer polarizer-type [J]. Journal of Applied Optics, 1988(6): 36-39,73. (in Chinese)
[12] Azzam R M A, Lopez Ali G. Accuratecalibration of the four-detector photopola-rimeter with imperfect polarizing optical elements [J]. Journal of the Optical Society of America A, 1989, 6(6): 1513-1521.
[13] Krishnan S. Calibration, properties, and applications of the division-of-amplitude photopolarimeter at 632.8 and 1523 nm [J]. Journal of the Optical Society of America A, 1992, 9(9): 001615. doi:  10.1364/JOSAA.9.001615
[14] Azzam R M A, Masetti E, Elminyawi I M, et al. Construction, calibration, and testing of a four etector photopolarimeter [J]. Review of Scientific Instruments, 1988, 59(1): 84-88. doi:  10.1063/1.1139971
[15] Azzam R M A. Arrangement of four photodetectors for measuring the state of polarization of light [J]. Optics Letters, 1985, 10(7): 309-311. doi:  10.1364/OL.10.000309
[16] Liao Yanbiao. Polarization of Optics[M]. Beijing: Science Press, 2003. (in Chinese)