Resolution of incremental photoelectric angular encoder with reference mark excursion
-
摘要: 介绍了增量式光电轴角编码器的工作原理及其在空间目标测量领域的应用。分析了轴角编码器零点漂移的原因,推导了基于轴系和球谐函数的望远镜系统误差修正模型。提出了采用外复核方法解算望远镜指向精度,即用前两天测星解算出来的系统球谐函数误差模型系数修正并复核当天的测星误差。设计了零点标定实验对轴角编码器零位进行标定,进行了连续11个晴天夜晚的观测实验,在零点标定前后观测在视场内均匀分布的30颗恒星,分别解算得到望远镜指向误差,确认了轴角编码器的零点漂移现象。采集GPS卫星数据进行了精度鉴定,望远镜方位和俯仰的轴系误差均值由13.99、11.50分别降至5.94、-3.49 ,验证了零点标定方法消除零位漂移并提高望远镜测量精度的可行性。Abstract: The operational principle and characteristic of incremental photoelectric angular encoder were summarized and discussed. And the reasons of reference mark excursion for incremental photoelectric angular encoder were analyzed. In order to validate reference mark excursion, a pointing function, which defined in the spherical coordinate of level mounting telescope, was expanded into series by spherical function. Then the spherical function model of pointing error was obtained. 30 stars scattered in sky space uniformly were selected to observe, through which the discrete value of 30 stars' pointing error were gained in longitude dimension and latitude dimension respectively. A new technique called external checking method, which used observing data two days ago to check intraday pointing error, was tested to validate the phenomenon of reference mark excursion. An experiment measuring pointing error before and after reference mark calibration by observing Polaris last 11 days. The results showed reference mark excursion caused pointing error of telescope becoming greater than the technical index designed. And after calibration the reference mark became fixed all night. To evaluate the effect of reference mark calibration, orbital position of a GPS satellite was measured by optoelectronic telescope. Pointing error of the telescope was gained compared with precision orbital position of GPS satellite. The results show that before reference mark calibration the mean azimuth and elevation error was 13.99, 11.50. And after calibration the mean azimuth and elevation error decreased to 5.94, -3.49 respectively. The experiment of GPS star observation showed that the reference mark calibration was available to eliminate reference mark excursion and to improve observation precision.
-
[1] [2] Shi Fengdong, Shi Yijun, Su Huanxin, et al. Design of pulley movement information collection system in space motion simulation platform[J]. Infrared and Laser Engineering, 2012, 41(11): 3093-3096. (in Chinese) [3] Wang Shuai, Wang Jianli, Chen Tao, et al. Application of the nonlinear tracking-differentiator in velocity estimation on optical encoder[J]. Infrared and Laser Engineering, 2009, 38(5): 849-853. (in Chinese) [4] 史风栋, 史屹君, 苏焕鑫,等. 空间运动模拟平台中的滑车运动信息采集系统设计[J]. 红外与激光工程, 2012, 41(11): 3093-3096. [5] [6] Tang Tianjin, Cao Xiangqun, Lin Bin. Developing current situation and the trend of photoelectric-angular encoder[J]. Optical Instruments, 2005, 27(1): 90-95. (in Chinese) [7] Chen Yun, Zhang Hongsheng. Coding modes of photoelectric shaft encoders and their developing trend[J]. Chinese Journal of Optics and Applied Optics, 2009, 2(2): 126-133. (in Chinese) [8] [9] 王帅, 王建立, 陈涛, 等. 非线性跟踪微分器在光电编码器测速中的应用[J]. 红外与激光工程, 2009, 38(5): 849-853. [10] Du Yingcai, Wang Xijun, Wang Shujie, et al. Auto-detection system of incremental encoder[J]. Journal of Electronic Measurement and Instrument, 2012, 26(11): 993-998. (in Chinese) [11] Xu Zhou, Hu Xiaodong, Luo Changzhou, et al. The electronic multiplication and interpolation of incremental optical encoder with reference mark[J]. Acta Photonica Sinica, 2002, 31(12): 1497-1550. (in Chinese) [12] [13] Zhao Jinyu, Wang Dexing, Li Wenjun, et al. New method of dynamic correciton for the system errors of telescope[J]. Infrared and Laser Engineering, 2005, 34(2): 244-247. (in Chinese) [14] [15] 汤天瑾, 曹向群, 林斌. 光电轴角编码器发展现状分析及展望[J]. 光学仪器, 2005, 27(1): 90-95. [16] Wang Jianjun, Lu Changming, Gao Xin, et al. Correction of the system errors of equatorial telescopes[J]. Journal of Spacecraft TTC Technology, 2012, 31(1): 47-50. (in Chinese) [17] [18] [19] [20] 杜颖财, 王希军, 王树洁,等. 增量式编码器自动检测系统[J]. 电子测量与仪器学报, 2012, 26(11): 993-998. [21] [22] [23] 徐洲, 胡晓东, 罗长洲, 等.增量式轴角编码器的电子细分及零位处理[J]. 光子学报, 2002, 31(12): 1497-1500. [24] [25] [26] 赵金宇, 王德兴, 李文军,等. 望远镜系统误差动态修正的一种新方法[J]. 红外与激光工程, 2005, 34(2): 244-247. [27] [28] [29] 王建军, 陆长明, 高昕, 等. 极轴式望远镜系统误差修正方法研究[J]. 飞行器测控学报, 2012, 31(1): 47-50.
计量
- 文章访问数: 354
- HTML全文浏览量: 53
- PDF下载量: 135
- 被引次数: 0