Volume 45 Issue 7
Aug.  2016
Turn off MathJax
Article Contents

Zhao Kun, Shi Xueshun, Liu Changming, Liu Yulong, Chen Haidong, Liu Hongbo, Chen Kunfeng, Li Ligong. Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors[J]. Infrared and Laser Engineering, 2016, 45(7): 705005-0705005(7). doi: 10.3788/IRLA201645.0705005
Citation: Zhao Kun, Shi Xueshun, Liu Changming, Liu Yulong, Chen Haidong, Liu Hongbo, Chen Kunfeng, Li Ligong. Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors[J]. Infrared and Laser Engineering, 2016, 45(7): 705005-0705005(7). doi: 10.3788/IRLA201645.0705005

Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors

doi: 10.3788/IRLA201645.0705005
  • Received Date: 2015-11-05
  • Rev Recd Date: 2015-12-03
  • Publish Date: 2016-07-25
  • In order to measure the absolute spectral responsivity of mid-infrared detectors with high accuracy, the improvement of power stability and beam quality of mid-infrared laser was theoretically and experimentally demonstrated. The power stability of mid-infrared laser was improved to be better than 0.1% by using acousto-optic modulator and feedback-control electronics. Based on propogation properties of Gaussion beam, the parameters were calculated and experimental setup of spatial filter was constructed. Owing to the spatial filter, the beam quality of mid-infrared laser was improved. A stable and reliable laser source is provided for the measurement of absolute spectral responsivity of mid-infrared detectors.
  • [1] Fan Jinxiang, Li Liang, Li Wenjun. Development of direct infrared countermeasure system and technology[J]. Infrared and Laser Engineering, 2015, 44(3):789-794. (in Chinese)范晋祥, 李亮, 李文军. 定向红外对抗系统与技术的发展[J]. 红外与激光工程, 2015, 44(3):789-794.
    [2] Xu Hanlie, Hu Xiuqing, Xu Na, et al. Discrimination and correction for solar contamination on mid-infrared band of FY-3C/VIRR[J]. Optics and Precision Engineering, 2015, 23(7):1874-1879. (in Chinese)徐寒列, 胡秀清, 徐娜, 等. FY-3C/可见光红外扫描辐射计中红外通道太阳污染的识别和修正[J]. 光学精密工程, 2015, 23(7):1874-1879.
    [3] Liu Jianguo, Liu Wenqing, Zhang Yujun, et al. Detection of formaldehyde using mid-infrared difference-frequency-based tunable absorption spectrometer at room temperature[J]. Infrared and Laser Engineering, 2006, 35(S):211-215.(in Chinese)刘建国, 刘文清, 张玉钧, 等. 差频中红外激光光谱技术探测大气甲醛污染研究[J]. 红外与激光工程, 2006, 35(S):211-215.
    [4] Hoyt C, Foukal P. Cryogenic radiometers and their application to the metrology[J]. Metrologia, 1991, 28(3):163-167.
    [5] Xueshun S, Kunfeng C, Hongyuan L, et al. Experimental study on absolute spectral responsivity value transfer with cryogenic radiometer[C]//SPIE, 2009, 7511:75111A-1-6.
    [6] Shi Xueshun, Chen Kunfeng, Wang Hengfei, et al. Experimental studies on Si trap detector absolute spectral responsivity calibration[J]. Optics Optoelectronic Technology, 2009, 7(5):63-65. (in Chinese)史学舜, 陈坤峰, 王恒飞, 等. 硅陷阱探测器绝对光谱响应率校准实验研究[J]. 光学与光电技术, 2009, 7(5):63-65.
    [7] Shi Xueshun, Liu Changming, Liu Yulong, et al. Absolute spectral responsivity of silicon trap detector based on absolute cryogenic radiometer[C]//the International Conference on Photonics and Optical Engineering, Proc.of SPIE, 2014, 9449:94490U-1-94490U-6.
    [8] Liu Changming, Shi Xueshun, Liu Yulong, et al. Determination of absolute spectral response and quantum efficiency of Si trap detector in band of 325-980 nm[J]. Journal of Optoeletronics Laser, 2015, 26(4):667-670. (in Chinese)刘长明, 史学舜, 刘玉龙, 等. 硅陷阱探测器在325~980 nm波段的绝对光谱响应率和量子效率测定[J]. 光电子激光, 2015, 26(4):667-670.
    [9] Liu Yulong, Liu Changming, Shi Xueshun, et al. Development of the transfer standard of near infrared absolute spectral response[J]. Journal of Astronautic Metrology and Measurement, 2015, 35(3):48-54. (in Chinese)刘玉龙, 刘长明, 史学舜, 等. 近红外绝对光谱响应度传递标准的研制[J]. 宇航计测技术, 2015, 35(3):48-54.
    [10] Pan Qikun. Progress of mid-infrared solid-state laser[J]. Chinese Optics, 2015, 8(4):557-566. (in Chinese)潘其坤. 中红外固体激光器研究进展[J]. 中国光学, 2015, 8(4):557-566.
    [11] Tan Gaijuan, Xie Jijiang, Zhang Laiming, et al. Recent progress in mid-infrared laser technology[J]. Chinese Optics, 2013, 6(4):501-512. 谭改娟, 谢冀江, 张来明, 等. 中波红外激光技术最新进展[J]. 中国光学, 2013, 6(4):501-512.
    [12] Su Hui, Li Zhiping, Duan Yanmin, et al. Intra-cavity singly resonant optical parametric oscillatro based on magnesium-doped periodically poled lithium niobate[J]. Optics and Precision Engineering, 2013, 21(6):1404-1409. (in Chinese)苏辉, 李志平, 段延敏,等. 基于掺镁周期极化铌酸锂晶体的内腔单共振连续可调谐光参量振荡器[J]. 光学精密工程, 2013, 21(6):1404-1409.
    [13] Sun Quanshe, Chen Kunfeng, Shi Xueshun. Mid infrared laser power stabilizer[J]. Infrared and Laser Engineering, 2015, 44(7):2127-2131. (in Chinese)孙权社, 陈坤峰, 史学舜. 中红外激光器功率稳定器技术[J]. 红外与激光工程, 2015, 44(7):2127-2131.
    [14] Gao Miao, Shao Xiaopeng, Wang Lin, et al. Power stabilization system of medium wave infrared laser based on acousto-optic modulator[J]. Infrared and Laser Engineering, 2015,44(7):1975-1979. (in Chinese)高苗, 绍晓鹏, 王琳,等. 基于声光调制的中波红外激光功率稳定系统[J]. 红外与激光工程, 2015, 44(7):1975-1979.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(515) PDF downloads(144) Cited by()

Related
Proportional views

Laser source used in accurate measurement of mid-infrared absolute spectral responsivity of detectors

doi: 10.3788/IRLA201645.0705005
  • 1. The 41 st Research Institute of CETC,Qingdao 266555,China;
  • 2. Science and Technology on Electronic Test & Measurement Laboratory,Qingdao 266555,China

Abstract: In order to measure the absolute spectral responsivity of mid-infrared detectors with high accuracy, the improvement of power stability and beam quality of mid-infrared laser was theoretically and experimentally demonstrated. The power stability of mid-infrared laser was improved to be better than 0.1% by using acousto-optic modulator and feedback-control electronics. Based on propogation properties of Gaussion beam, the parameters were calculated and experimental setup of spatial filter was constructed. Owing to the spatial filter, the beam quality of mid-infrared laser was improved. A stable and reliable laser source is provided for the measurement of absolute spectral responsivity of mid-infrared detectors.

Reference (14)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return