Volume 47 Issue 3
Apr.  2018
Turn off MathJax
Article Contents

Tian Yuqi, Gao Tianyuan, Zhao Yu, Fu Yuegang. Angle error of bionic compound eye imaging system[J]. Infrared and Laser Engineering, 2018, 47(3): 310001-0310001(5). doi: 10.3788/IRLA201847.0310001
Citation: Tian Yuqi, Gao Tianyuan, Zhao Yu, Fu Yuegang. Angle error of bionic compound eye imaging system[J]. Infrared and Laser Engineering, 2018, 47(3): 310001-0310001(5). doi: 10.3788/IRLA201847.0310001

Angle error of bionic compound eye imaging system

doi: 10.3788/IRLA201847.0310001
  • Received Date: 2017-10-05
  • Rev Recd Date: 2017-11-23
  • Publish Date: 2018-03-25
  • In order to realize the error analysis of the bionic compound eye imaging system, a method of error analysis was introduced. The mathematical model was established. By finding the conversion matrix of the coordinate system, the transformation between the geodetic coordinate and the coordinate system with the subeye as the original point was realized. The equation of quantity relation between the rotation angle and the parameters of the bionic compound eye, that is, the measurement equation of the system, was derived. By using the method of function error, the measurement equation was transformed into an error function equation, and the error analysis was carried out. The experiment was set up, and the experimental data were collected. The feasibility of the analysis method was verified by comparing the calculated values with the actual measurement data. Theory calculated rotation angle systematic error is 3'14. Actual measured rotation angle error is 3'15. The calculated value of the theory is in agreement with the actual measured value, which proves that the error analysis method is feasible.
  • [1] Lei Weining, Guo Yunzhi, Gao Tingting. Study on the structure system with large field detection based on bionic compound eye[J]. Optics Optoelectronic Technology, 2016, 14(3):62-66. (in Chinese)
    [2] Jiang Xin, Gong Huixin, Ding Lei, et al. Choice of image sensor in high-speed small target imaging system[J]. Infrared and Laser Engineering, 2007, 36(S2):513-516. (in Chinese)
    [3] Gong Xianwei. Study on imaging system of curved surface biomimetic compound eye[D]. Beijing:University of Chinese Academy of Sciences, 2012. (in Chinese)
    [4] Chen Mingjun, Liu Yesheng, Li Zi'ang, et al. New reserch progress in design and manufaure of artificial optical compound eye[J]. Journal of Mechanical Engineering, 2011, 47(1):161-168. (in Chinese)
    [5] Tanida J, Kumagai T, Yamada K, et al. Thin observation module by bound optics (TOMBO):an optoelectronic image capturing system[C]//International Topical Meeting on Optics in Computing, International Society for Optics and Photonics, 2000:1030-1036.
    [6] Duparr J, Schreiber P, Matthes A, et al. Microoptical telescope compound eye[J]. Optics Express, 2005, 13(3):889-903.
    [7] Di Si, Xu Honghui, Du Ruxu. New progress of artificial compound eye imaging systems[J]. Optics Optoelectronic Technology, 2008, 6(4):93-96. (in Chinese)
    [8] Zhang Hongxin, Lu Zhengwu, Wang Ruiting, et al. Study on curved compound eye imaging system[J]. Optics and Precision Engineering, 2006, 14(3):346-350. (in Chinese)
    [9] Gong Xianwei, Yu Weixing, Zhang Hongxing, et al. Progress in design and fabrication of artificial compound eye optical system[J]. Chinese Optics, 2013, 6(1):34-45. (in Chinese)
    [10] Brady D J, Gehm M E, Stack R A, et al. Multiscale gigapixel photography[J]. Nature, 2012, 486(7403):386-389.
    [11] Feng Guoyu. Research on technique of image mosaic of multiple model in large view scene[D]. Changsha:National University of Defense Technology, 2007. (in Chinese)
    [12] Xu Yan, Yan Shuhua, Zhou Chunlei, et al. Advances in bionic study on insects compound eyes[J]. Optical Technique, 2006, 32(S1):10-12. (in Chinese)
    [13] Cai Mengyin, Xu Guili. Fast bionic image mosaic method on large field of view[J]. Transducer and Microsystem Technologies, 2007, 26(12):82-84. (in Chinese)
    [14] Cheng Mingjun, Liu Yesheng, Li Zi'ang, et al. New research progress in design manufacture of artificial optical compound eye[J]. Journal of Mechanical Engineering, 2011, 47(1):161-168. (in Chinese)
    [15] Wang Lijuan. Research on target ranging and high resolution image reconstruction based on multi-aperture imager[D]. Xi'an:Xi'an University of Science and Technology, 2012. (in Chinese)
    [16] Fu Yuegang, Zhao Yu, Liu Zhiying, et al. Design of the bionic compound eye optical system based on field splicing method[J]. Chinese Journal of Scientific Instrument, 2015, 36(2):422-429. (in Chinese)
    [17] Gao Tianyuan, Dong Zhengchao, Zhao Yu, et al. Structure and Alignment of field stitching compound eye optical imaging system[J]. Acta Photonica Sinica, 2014, 43(11):43-48. (in Chinese)
    [18] Yang Zhichao. Error Theory[M]. Changsha:Central South University of Technology Press, 1987. (in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(541) PDF downloads(54) Cited by()

Related
Proportional views

Angle error of bionic compound eye imaging system

doi: 10.3788/IRLA201847.0310001
  • 1. School of Opto-electronic Engineering,Changchun University of Science and Technology,Changchun 130022,China

Abstract: In order to realize the error analysis of the bionic compound eye imaging system, a method of error analysis was introduced. The mathematical model was established. By finding the conversion matrix of the coordinate system, the transformation between the geodetic coordinate and the coordinate system with the subeye as the original point was realized. The equation of quantity relation between the rotation angle and the parameters of the bionic compound eye, that is, the measurement equation of the system, was derived. By using the method of function error, the measurement equation was transformed into an error function equation, and the error analysis was carried out. The experiment was set up, and the experimental data were collected. The feasibility of the analysis method was verified by comparing the calculated values with the actual measurement data. Theory calculated rotation angle systematic error is 3'14. Actual measured rotation angle error is 3'15. The calculated value of the theory is in agreement with the actual measured value, which proves that the error analysis method is feasible.

Reference (18)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return