Volume 48 Issue 9
Oct.  2019
Turn off MathJax
Article Contents

Wang Zhiming, Zhou Dong, Guo Qi, Li Yudong, Wen Lin, Ma Lindong, Zhang Xiang, Cai Yulong, Liu Bingkai. Study on the mechanism of dark current degradation of HgCdTe photovoltaic devices induced by γ-irradiation[J]. Infrared and Laser Engineering, 2019, 48(9): 916001-0916001(8). doi: 10.3788/IRLA201948.0916001
Citation: Wang Zhiming, Zhou Dong, Guo Qi, Li Yudong, Wen Lin, Ma Lindong, Zhang Xiang, Cai Yulong, Liu Bingkai. Study on the mechanism of dark current degradation of HgCdTe photovoltaic devices induced by γ-irradiation[J]. Infrared and Laser Engineering, 2019, 48(9): 916001-0916001(8). doi: 10.3788/IRLA201948.0916001

Study on the mechanism of dark current degradation of HgCdTe photovoltaic devices induced by γ-irradiation

doi: 10.3788/IRLA201948.0916001
  • Received Date: 2019-04-05
  • Rev Recd Date: 2019-05-10
  • Publish Date: 2019-09-25
  • Aiming at the problem that the infrared detector is degraded by the high-energy particle irradiation in the space application, the effect of -ray on the dark current of the medium-wave HgCdTe photovoltaic device was studied. The HgCdTe device was irradiated with 60Co- rays at room temperature and 77 K. After the irradiation test, the low temperature irradiated device was subjected to 77 K low temperature annealing and room temperature annealing. By comparing the I-V characteristics, R-V characteristics and zero-bias dynamic resistance R0 parameters of the device before and after irradiation, the influence mechanism of -irradiation on the dark current of the HgCdTe device was analyzed. The test results show that the dark current of the device does not show obvious degradation after irradiation at room temperature under the total dose of 7 mrad(Si). Under 77 K temperature irradiation conditions, the dark current of the device increases with the dose, and the dark current degradation amplitude is related to the bias during the irradiation test. Studies have shown that the degradation of dark current was caused by gamma irradiation causing ionization damage in the device, resulting in an increase in the interface state and hole trap charge density in the device's CdTe passivation layer.
  • [1] Pickel J C, Kalma A H, Hopkinson G R, et al. Radiation effects on photonic imagers-a historical perspective[J]. IEEE Transactions on Nuclear Science, 2003, 50(3):671-688.
    [2] Rogalski A. Next decade in infrared detectors[C]//SPIE,2017, 10433:1-25.
    [3] Sizov F F, Lysiuk I O, Gumenjuk-Sichevska J V, et al. Gamma radiation exposure of MCT diode arrays[J]. Semiconductor Science and Technology, 2006, 21(3):358-363.
    [4] Lee M Y, Kim Y H, Lee N H, et al. A comparison of gamma radiation effects on bromine-and hydrazine-treated HgCdTe photodiodes[J]. Journal of Electronic Materials, 2006, 35(6):1429-1433.
    [5] Lee N H, Cho J W, Kim S H, et al. A study on a radiation hardening of an infrared detector[J]. Journal of Nuclear Science and Technology, 2008, 45(5):564-567.
    [6] Hu X W, Fang J X, Wang Q, et al. A deep level induced by gamma irradiation in Hg1-xCdxTe[J]. Applied Physics Letters, 1998, 73(1):91-92.
    [7] Hu X W, Zhu K X, Li X, et al. Influence of gamma irradiation on the performance of HgCdTe photovoltaic devices[C]//SPIE, 1999, 3698:920-924.
    [8] Qiao Hui, Liao Yi, Hu Weida, et al. Research on real-time radiation effects of HgCdTe planar photovoltaic devices[J]. Acta Phys Sin, 2008, 57(11):7088-7093. (in Chinese)
    [9] Qiao Hui, Deng Yi, Hu Weida, et al. Study on irradiation effects of long-wavelength HgCdTe photovoltaic detectors with different passivate layers[J]. J Infrared Millim Wave, 2010, 29(1):6-10. (in Chinese)
    [10] Qiao H, Hu W D, Li T, et al. Electrical characteristics of mid-wavelength HgCdTe photovoltaic detectors exposed to gamma iradiation[J]. Journal of Electronic Materials, 2016, 45(9):4640-4645.
    [11] Yang Jianrong. Physics and Technology of HgCdTe Materials[M]. Beijing:National Defense Industry Press, 2012. (in Chinese)
    [12] Moriwaki M M, Srour J R, Lou L F, et al. Ionizing radiation effects on HgCdTe MIS devices[J]. IEEE Transactions on Nuclear Science, 1990, 37(6):2034-2041.
    [13] Fleetwood D M. Evolution of total ionizing dose effects in MOS devices with moore's law scaling[J]. IEEE Transactions on Nuclear Science, 2017, 99(12):1-17.
    [14] Mueller H H, Schulz M. Individual interface traps at the Si-SiO2 interface[J]. Journal of Materials Science:Materials in Electronics, 1995, 6(2):65-74.
    [15] Hopkinson G R. Radiation-induced dark current increases in CCDs[C]//IEEE, 1993:401-408.
    [16] Boch J, Saigne F, Schrimpf R D, et al. Elevated temperature irradiation at high dose rate of commercial linear bipolar ICs[J]. IEEE Transactions on Nuclear Science, 2004, 51(5):2903-2907.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(573) PDF downloads(57) Cited by()

Related
Proportional views

Study on the mechanism of dark current degradation of HgCdTe photovoltaic devices induced by γ-irradiation

doi: 10.3788/IRLA201948.0916001
  • 1. Xinjiang Technical Institute of Physics and Chemistry,Chinese Academy of Sciences,Urumqi 830011,China;
  • 2. University of Chinese Academy of Sciences,Beijing 100049,China

Abstract: Aiming at the problem that the infrared detector is degraded by the high-energy particle irradiation in the space application, the effect of -ray on the dark current of the medium-wave HgCdTe photovoltaic device was studied. The HgCdTe device was irradiated with 60Co- rays at room temperature and 77 K. After the irradiation test, the low temperature irradiated device was subjected to 77 K low temperature annealing and room temperature annealing. By comparing the I-V characteristics, R-V characteristics and zero-bias dynamic resistance R0 parameters of the device before and after irradiation, the influence mechanism of -irradiation on the dark current of the HgCdTe device was analyzed. The test results show that the dark current of the device does not show obvious degradation after irradiation at room temperature under the total dose of 7 mrad(Si). Under 77 K temperature irradiation conditions, the dark current of the device increases with the dose, and the dark current degradation amplitude is related to the bias during the irradiation test. Studies have shown that the degradation of dark current was caused by gamma irradiation causing ionization damage in the device, resulting in an increase in the interface state and hole trap charge density in the device's CdTe passivation layer.

Reference (16)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return