  • For the development trend of miniaturization and high-resolution of spectrometer, an optical design with a simple structure, broadband, astigmatism-corrected micro spectrometer was designed. The principle and correction method of the aberration of crossed beam czerny-turner spectrometer were analyzed in detail. The broadband astigmatism-corrected theory equations using cylindrical lens were deduced. For example, a micro spectrometer operating in 300-900 nm with an object NA of 0.08 has been designed. This spectrometer adopted crossed beam structure to minish its volume and used a cylindrical lens to remove astigmatism over the full bandwidth. The analyzed results demonstrated that this spectrometer with compact configuration and small volume corrected the astigmatism in the wide spectral region. The resolution of the spectrometer was better than 0.5 nm in the whole spectral region.
  • [1] Jia Hui, Yao Yong. Characteristics of typical optical systems with diffractive gratings of micro-spectrometers and improvement of spectrometer's resolution [J]. Spectroscopy and Spectral Analysis, 2007, 27 (8): 1653-1656. (in Chinese) 贾辉, 姚勇. 微小型光栅光谱仪光学系统的特点与光谱分 辨率的提高[J]. 光谱学与光谱分析, 2007, 27 (8): 1653-1656.
    [2]
    [3]
    [4] Li Hongsheng, Liao Yanbiao. Fiber slit spectrometer MTF measurement by using grating ghost line and Fourier analysis[J]. Infrared and Laser Engineering, 2012, 41(3): 770-774. (in Chinese) 李宏升, 廖延彪. 利用鬼线及傅里叶分析测量光纤狭缝光 谱仪MTF[J]. 红外与激光工程, 2012, 41(3): 770-774.
    [5]
    [6] Lin Zhong, Fan Shifu. Spectral Instruments [M]. Beijing: China Machine Press, 1988: 114-118. (in Chinese) 林中, 范世福. 光谱仪器学[M]. 北京: 机械工业出版社, 1988: 114-118.
    [7] Czerny M, Turner A. ber den Astigmatismus bei Spiegelspektrometern[J]. Z Phys, 1930, A (61): 792-797.
    [8]
    [9] Arthur B Shafer, Lawrence R Megill, Leann Droppleman. Optimization of the Czerny-Turner spectrometer [J]. J Opt Soc Am, 1964, 54: 879-887.
    [10]
    [11]
    [12] Cheng Peng. Design principles and parameters analysis of a small grating spectrometer[D]. Kunming: Kunming University of Science and Technology, 2008: 36-37. (in Chinese) 程鹏. 一种小型光栅光谱仪的设计原理及参数分析[D]. 昆 明: 昆明理工大学, 2008: 36-37.
    [13] Xue Qingsheng, Chen Wei. Design of modified Czerny-Turner spectral imaging system with wide spectral region [J]. Optics and Precision Engineering, 2012, 20 (2): 233-240. (in Chinese) 薛庆生,陈伟. 改进的宽谱段车尔尼-特纳光谱成像系统设 计[J]. 光学精密工程, 2012, 20(2): 233-240.
    [14]
    [15] Austin D R, Witting T, Walmsley I A. Broadband astigmatism-free Czerny-Turner imaging spectrometer using spherical mirrors[J]. Applied Optics, 2009, 48(19): 3846-3853.
    [16]
    [17] Xue Qingsheng, Wang Shurong, Lu Fengqin. Aberration correction of Czerny-Turner imaging spectrometer carried by satellite [J]. Acta Optica Sinica, 2008, 29 (1): 35-40. (in Chinese) 薛庆生, 王淑荣, 鲁凤芹. 星载车尔尼-特纳型成像光谱仪 像差校正的研究[J]. 光学学报, 2008, 29(1): 35-40.
    [18]
    [19]
    [20] Rosendahl G R. Contributions to the optics of mirror systems and gratings with oblique incidence III Some applications[J]. J Opt Soc Am, 1962, 52(4): 412-415.
    [21] Kong Peng, Tang Yuguo, Bayanheshig, et al. Optimization of broad-band flat-field holographic concave grating without astigmatism[J]. Spectroscopy and Spectral Analysis, 2012, 32 (2): 565-569. (in Chinese) 孔鹏, 唐玉国, 巴音贺希格, 等. 零像散宽波段平场全息凹面光栅的优化设计[J]. 光谱学与光谱分析, 2012, 32(2): 565-569.
    [22]
    [23] Ji Yiqun, Shen Weimin. Design and manufacture of Offner convex grating hyper-spectral imager[J]. Infrared and Laser Engineering, 2010, 39(2): 285-287. (in Chinese) 季轶群, 沈为民. Offner 凸面光栅超光谱成像仪的设计与 研制[J]. 红外与激光工程, 2010, 39(2): 285-287.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(924) PDF downloads(594) Cited by()

Related
Proportional views

Optical system design of broadband astigmatism-free czerny-turner spectrometer

  • 1. Xi'an Institute of Optics and Precision Mechanics,Chinese Academy of Sciences,Xi'an 710119,China;
  • 2. University of Chinese Academy of Sciences,Beijing 100049,China

Abstract: For the development trend of miniaturization and high-resolution of spectrometer, an optical design with a simple structure, broadband, astigmatism-corrected micro spectrometer was designed. The principle and correction method of the aberration of crossed beam czerny-turner spectrometer were analyzed in detail. The broadband astigmatism-corrected theory equations using cylindrical lens were deduced. For example, a micro spectrometer operating in 300-900 nm with an object NA of 0.08 has been designed. This spectrometer adopted crossed beam structure to minish its volume and used a cylindrical lens to remove astigmatism over the full bandwidth. The analyzed results demonstrated that this spectrometer with compact configuration and small volume corrected the astigmatism in the wide spectral region. The resolution of the spectrometer was better than 0.5 nm in the whole spectral region.