  • On thermal test of aerospace research filed, wind tunnel is usually used for heating the sample up to 1 700℃. It is very difficult to measure dynamic temperature filed without using the expensive and non-flexible temperature metrical IR-camera. Based on colorimetric model, two selected near-infrared wavelengths near 900 nm were used and a high dynamic response CCD device was hired. Mechanic and optical design guaranteed space synchronization of collected images of two measurement tunnel. The device achieved temperature filed measurement, frame rate is up to 40 Hz, and the measurement accuracy is less than 6%.
  • [1]
    [2] Gathers G R. Analysis of multiwave length pyrometry using nonlinear chi-square fits and Monte Carlo methods [J]. International Journal of Thermophysics, 1992(3): 50-55.
    [3] Liu Yingqi. Inversion of temperature distribution of space target infrared multi band[J]. Infrared and Laser Engineering, 2013, 3(1): 10-12. (in Chinese)
    [4]
    [5]
    [6] Gong Haimei, Liu Dafu. Develovments and trends in spaceborne infrared detectors [J]. Infrared and Laser Engineering, 2008, 37(1): 18-24. (in Chinese)
    [7] Zhang Baosheng, Jiao Xiangdong, Lv Tao, et al. High temperature measurement technology and its application in the welding [J]. Journal of Beijing Institute of Petro-Chemical Technology, 2006(2): 22-23. (in Chinese)
    [8]
    [9] Wang Yutian, Yang Lili, Lu Xinqiong. Transient high temperature measurement system [J]. Piezoelectrics Acoustooptics, 2010(3): 45-46. (in Chinese)
    [10]
    [11] Deng Xingkai, Yang Yongjun. Application and development of CCD multispectral radiation thermometry [J]. Metrology Measurement Technology, 2011(1): 101-102. (in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(307) PDF downloads(253) Cited by()

Related
Proportional views

Dynamic high temperature field measurement device

  • 1. Tianjin Bureau of China Naval Equipment Ministry,Beijing 100073,China;
  • 2. Air-ship Missile Military Representative Office of Navy in Beijing,Beijing 100854,China;
  • 3. Beijing Zhenxing Institute of Metrology and Measurement,Beijing 100074,China

Abstract: On thermal test of aerospace research filed, wind tunnel is usually used for heating the sample up to 1 700℃. It is very difficult to measure dynamic temperature filed without using the expensive and non-flexible temperature metrical IR-camera. Based on colorimetric model, two selected near-infrared wavelengths near 900 nm were used and a high dynamic response CCD device was hired. Mechanic and optical design guaranteed space synchronization of collected images of two measurement tunnel. The device achieved temperature filed measurement, frame rate is up to 40 Hz, and the measurement accuracy is less than 6%.

Reference (11)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return