Wang Yiqun, Gao Zhiliang. Design and test of imaging spectrometer’s dual dispersive prisms[J]. Infrared and Laser Engineering, 2014, 43(6): 1982-1987.
Citation: Wang Yiqun, Gao Zhiliang. Design and test of imaging spectrometer’s dual dispersive prisms[J]. Infrared and Laser Engineering, 2014, 43(6): 1982-1987.

Design and test of imaging spectrometer’s dual dispersive prisms

  • Received Date: 2013-10-22
  • Rev Recd Date: 2013-11-23
  • Publish Date: 2014-06-25
  • Dual dispersive prisms are the key dispersive component of high resolution space-borne imaging spectrometer. Their opto-mechanical mounting is an important problem which must be resolved during imaging spectrometer engineering development phase. Firstly, the working principle of dual dispersive prisms was introduced and their opto-mechanical mounting requirements were also presented. Furthermore, after taking into account coefficient of expansion matching, density, modulus of elasticity, machining property and so on, dual dispersive prisms mounting material was confirmed. Moreover, the great difference of coefficient of expansion between one of dual dispersive prisms and its mounting material was compensated using the temperature compensation method. Afterward, the dual dispersive prisms were mounted by the semikinematic mounting method. Finally, Mechanics analysis and thermoanalysis results were proposed, subsequently corresponding tests were also carried out. Tests results indicate that the nature frequency of dual dispersive prisms assembly is 301.5 Hz, integrative OPD of dual dispersive prisms assembly is better than 0.021 (=632.8 nm) at 20℃ 5℃ . The results proved the dual dispersive prisms assembly satisfied the requirements of imaging spectrometer.
  • [1] Liu Xiaomei, Xiang Yang. Design of telecentric off-axis three-mirror system of imaging spectrometer with wide field of view[J]. Acta Optica Sinica, 2011, 31(6): 0622004. (in Chinese) 刘晓梅, 向阳. 宽视场成像光谱仪前置远心离轴三反光学系统设计[J]. 光学学报, 2011, 31(6): 0622004.
    [2]
    [3] Xue Qingsheng, Huang Yu, Lin Guanyu. Optical system design of wide-angle and high-resolution spaceborne imaging spectrometer[J]. Acta Optica Sinica, 2011, 31(8): 0822001. (in Chinese) 薛庆生, 黄煜, 林冠宇. 大视场高分辨力星载成像光谱仪光学系统设计[J]. 光学学报, 2011, 31(8): 0822001.
    [4]
    [5] Zhang Junqiang, Yan Changxiang, Lin Chao. Thermal effect on spectral-line shift of spaceborne imaging pectrometer[J]. Acta Optica Sinica, 2012, 32(5): 0528001. (in Chinese) 张军强, 颜昌翔, 蔺超. 温度对星载成像光谱仪谱线漂移的影响[J]. 光学学报, 2012, 32(5): 0528001.
    [6]
    [7] Liu Jifan, Ma Yanhua, Zhang Lei, et al. New hyperspectral imaging system based on AOTF[J]. Infrared and Laser Engineering, 2013, 42 ( 11 ): 3065-3069. ( in Chinese) 刘济帆, 马艳华, 张雷, 等. 基于AOTF 的新型成像光谱系统[J]. 红外与激光工程, 2013, 42(11): 3065-3069.
    [8]
    [9] Gong Dun, Wang Hong. Optical design of hyperspectral imaging spectrometer on space[J]. Infrared and Laser Engineering, 2014, 43(2): 541-545. (in Chinese) 巩盾, 王红. 空间高光谱成像仪的光学设计[J]. 红外与激光工程, 2014, 43(2): 541-545.
    [10]
    [11]
    [12] Wang Yiqun, Yan Changxiang, Miao Chun'an. Choice of spectral-splitting modes in space-borne hyper-spectral imager[J]. Chinese Journal of Optics and Applied Optics, 2009, 2(4): 304-308. (in Chinese) 汪逸群, 颜昌翔, 苗春安. 星载高分辨力超光谱成像仪分光方式的选择[J]. 中国光学与应用光学, 2009, 2(4): 304-308.
    [13]
    [14] Zhang Juan, Liu Liren, Zhou Yu, et al. Design of a new type interleaver[J]. Acta Optica Sinica, 2003, 23(12): 1424-1428. (in Chinese) 张娟, 刘立人, 周煜, 等. 一种新型的光交错复用器的设计[J]. 光学学报, 2003, 23(12): 1424-1428.
    [15] Paul R Yoder. Opto-Mechanical Systems Design[M]. 3rd ed. Zhou Haixian, Cheng Wengfang, Translated. Beijing: China Machine Press, 2008: 349-369. (in Chinese)
    [16]
    [17] Shao Jun. Investigation on support structure of special reflector[J]. Infrared, 2006. 27(4): 36-41. (in Chinese) 邵君. 空间反射镜支撑结构研究概述[J]. 红外, 2006, 27(4): 36-41.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(392) PDF downloads(134) Cited by()

Related
Proportional views

Design and test of imaging spectrometer’s dual dispersive prisms

  • 1. Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China

Abstract: Dual dispersive prisms are the key dispersive component of high resolution space-borne imaging spectrometer. Their opto-mechanical mounting is an important problem which must be resolved during imaging spectrometer engineering development phase. Firstly, the working principle of dual dispersive prisms was introduced and their opto-mechanical mounting requirements were also presented. Furthermore, after taking into account coefficient of expansion matching, density, modulus of elasticity, machining property and so on, dual dispersive prisms mounting material was confirmed. Moreover, the great difference of coefficient of expansion between one of dual dispersive prisms and its mounting material was compensated using the temperature compensation method. Afterward, the dual dispersive prisms were mounted by the semikinematic mounting method. Finally, Mechanics analysis and thermoanalysis results were proposed, subsequently corresponding tests were also carried out. Tests results indicate that the nature frequency of dual dispersive prisms assembly is 301.5 Hz, integrative OPD of dual dispersive prisms assembly is better than 0.021 (=632.8 nm) at 20℃ 5℃ . The results proved the dual dispersive prisms assembly satisfied the requirements of imaging spectrometer.

Reference (17)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return