Li Shuang, Qiu Zhenwei. Polarization orientation calibration of simultaneous imaging polarimeter[J]. Infrared and Laser Engineering, 2014, 43(12): 4100-4104.
Citation: Li Shuang, Qiu Zhenwei. Polarization orientation calibration of simultaneous imaging polarimeter[J]. Infrared and Laser Engineering, 2014, 43(12): 4100-4104.

Polarization orientation calibration of simultaneous imaging polarimeter

  • Received Date: 2014-04-10
  • Rev Recd Date: 2014-05-10
  • Publish Date: 2014-12-25
  • The Simultaneous Imaging Polarimetry (SIP)is a new type of remote sensing detection technology. The imaging polarimetry architecture refered in the paper is Division of Amplitude, which can simultaneously obtain four polarization intensity images (in the orientation angle of 0,45,90 and 135 degree)of the same target on the same detector. Affected by self -polarization, error of polarization element and coating of the system, the orientation angle of polarization will be deviated. In order to ensure the polarization measurement accuracy, the orientation angle of polarization was calibrated using two methods (Equator-Poles calibration and curve fitting). Results show that the difference between these two methods is less than 0.4%, and degree of linear polarization (DOLP) accuracy of measurement and principle calculation is all within 2%, which prove the effect of the calibration.
  • [1]
    [2] Tyo J S, Goldstein D L, Chenault D B, Review of passive imaging polarimetry for remote sensing applications [J]. Appled Optics, 2006, 45(22): 5453-5469.
    [3] Kenta, Fujita, Maiko, Development of simultaneous imaging polarimeter[C]//SPIE, 2006: 6269, 62693D.
    [4]
    [5]
    [6] Fujita K, Itoh Y, Mukai T. Development of simultaneous imaging polarimeter for asteroids [J]. Advances in Space Research, 2009, 43: 325-327.
    [7]
    [8] Li Shuang, Qiu Zhenwei, Yang Changjiu. Preliminary study on the detection technology of simultaneous imaging polarization (SIP) [J]. Journal of Atmospheric and Enviroment Optics, 2010, 5(3): 198-202. (in Chinese) 李双, 裘桢炜, 杨长久, 同时偏振成像探测技术初探[J]. 大 气与环境光学学报, 2010, 5(3): 198-202.
    [9]
    [10] Yang Changjiu. Studies on calibration and information pro-cessing of simultaneous imaging polarimeter [D]. Hefei: An-hui Institute of Optical and Fine Mechanics, Chinese Acade-my of Sciences, 2012. (in Chinese) 杨长久. 同时偏振成像仪定标与信息处理研究[D]. 合肥: 中国科学院安徽光学精密机械研究所, 2012.
    [11] Azzam R M A. Instrument matrix of the four-detector photopolarimeter: physical meaning of its rows and columns and constraints on its elements [J]. J Opt Soc Am A, 1990, 7(1): 87-91.
    [12]
    [13] Azzam R M A, Lopez A G. Accurate calibration of the four-detector photopolarimeter with imperfect polarizing optical elements [J]. J Opt Soc Am A, 1989, 6(10): 1513-1521.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(317) PDF downloads(174) Cited by()

Related
Proportional views

Polarization orientation calibration of simultaneous imaging polarimeter

  • 1. Key Laboratory of Optical Calibration and Characterization,Optical Remote Sensing Center,Anhui Institute of Optical and Fine Mechanics,Chinese Academy of Sciences,Hefei 230031,China

Abstract: The Simultaneous Imaging Polarimetry (SIP)is a new type of remote sensing detection technology. The imaging polarimetry architecture refered in the paper is Division of Amplitude, which can simultaneously obtain four polarization intensity images (in the orientation angle of 0,45,90 and 135 degree)of the same target on the same detector. Affected by self -polarization, error of polarization element and coating of the system, the orientation angle of polarization will be deviated. In order to ensure the polarization measurement accuracy, the orientation angle of polarization was calibrated using two methods (Equator-Poles calibration and curve fitting). Results show that the difference between these two methods is less than 0.4%, and degree of linear polarization (DOLP) accuracy of measurement and principle calculation is all within 2%, which prove the effect of the calibration.