Volume 43 Issue S1
Jan.  2015
Turn off MathJax
Article Contents

Zheng Liangliang. Correction of non-uniformity response for multiple output TDI CCD imaging system[J]. Infrared and Laser Engineering, 2014, 43(S1): 145-150.
Citation: Zheng Liangliang. Correction of non-uniformity response for multiple output TDI CCD imaging system[J]. Infrared and Laser Engineering, 2014, 43(S1): 145-150.

Correction of non-uniformity response for multiple output TDI CCD imaging system

  • Received Date: 2014-10-13
  • Rev Recd Date: 2014-11-16
  • Publish Date: 2015-01-25
  • To solve the non-uniformity response of multiple outputs in TDI CCD imaging systems, every factors that may influence the non-uniformity response were analyzed in detail according to the flow of video signal process. Compared with popular correction methods of non-uniformity response, an improved method based on single point calibration was proposed, which integrated the advance of single-point correction and two-point correction methods. The improved single-point method has the features of simple algorithm, high efficiency, good practical application, low work of measurement, and so on. The results of experiments show that the non-uniformity response of TDI CCD imaging system declines from 3.5% to 1.5% according to the images using the improved method of single point calibration. The maximum of non-uniformity responses among multiple outputs is less than 2.5% during the full response range. The improved method of single-point calibration can satisfy the requirements of TDI CCD image systems and be practical in engineering.
  • [1]
    [2] Xu Wenwen, Zhou Jianyong, Tang Zunlie, et al. Synthesis and non-uniformity correction of TDI CCD multi-tap's imaging[J]. Semiconductor Optoelectronics, 2009, 30(1): 153-155. (in Chinese) 徐文文,周建勇,唐遵烈,等. TDI CCD多抽头图像合成及非均匀性校正[J]. 半导体光电, 2009, 30(1): 153-155.
    [3] Wu Houde, Xu Wenhai. Correction of seams for multiple output CCD[J]. Optics and Precision Engineering, 2013, 21(2): 454-461. (in Chinese) 吴厚德,许文海. 多输出CCD接缝的校正[J]. 光学 精密工程, 2013, 21(2): 454-461.
    [4]
    [5]
    [6] Ning Yonghui, Gou Yongfei. Correction of pixel response non-uniformity in TDI CCD mosaic camera[J]. Chinese Optics, 2013, 6(3): 386-394. (in Chinese) 宁永慧,郭永飞. TDI CCD拼接相机的像元响应非均匀性校正方法[J]. 中国光学, 2013, 6(3): 386-394.
    [7]
    [8] Yue Junhua, Li Yan, Wu Xueying, et al. Correction of imaging non-uniformity for multi-TDI CCD mosaic camera[J]. Optics and Precision Engineering, 2009, 17(2): 3084-3088. (in Chinese) 岳俊华,李岩,武学颖,等. 多TDI-CCD拼接相机成像非均匀性的校正[J]. 光学 精密工程, 2009, 17(12): 3084-3088.
    [9] Liu Yanyan, Li Guoning, Zhang Yu, et al. Detection and correction of response non-uniformity based on visible light area CCD[J]. Chinese Journal of Liquid Crystal and Displays, 2010, 25(5): 759-763. (in Chinese) 刘妍妍,李国宁,张瑜,等. 可见光面阵CCD响应非均匀性的检测与校正[J]. 液晶与显示, 2010, 25(5): 759-763.
    [10]
    [11] Lin Hui, Liu Lili, Tian Xinfeng, et al. Correct non-uniformity of scientific grade CCD in measuring laser near field distributing[J]. Infrared and Laser Engineering, 2014, 43(7): 2108-2111. (in Chinese) 蔺辉,刘立力,田新锋,等. 强激光近场分布测量中科学级CCD的非均匀性校正[J]. 红外与激光工程, 2014, 43(7):2108-2111.
    [12]
    [13] Qu Hongfeng, Wang Xiaodong, Lv Baolin. Non-uniformity correction of multiple output area CCD image[J]. Chinese Journal of Liquid Crystal and Displays, 2012, 27(4): 569-572. (in Chinese) 曲洪丰,王晓东,吕宝林. 多通道输出面阵CCD图像非均匀性校正[J]. 液晶与显示, 2012, 27(4): 569-572.
    [14]
    [15] Liu Zexun, Quan Xianrong, Ren Jianwei, et al. Calibration of CCD camera's output non-uniformity linear corrected coefficient[J]. Infrared and Laser Engineering, 2012, 41(8): 2211-2215. (in Chinese) 刘则洵,全先荣,任建伟,等. CCD相机输出非均匀性线性校正系数的定标[J]. 红外与激光工程, 2012, 41(8): 2211-2215.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(279) PDF downloads(245) Cited by()

Related
Proportional views

Correction of non-uniformity response for multiple output TDI CCD imaging system

  • 1. National & Local United Engineering Research Center of Small Satellite Technology,Changchun Institute of Optics fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China

Abstract: To solve the non-uniformity response of multiple outputs in TDI CCD imaging systems, every factors that may influence the non-uniformity response were analyzed in detail according to the flow of video signal process. Compared with popular correction methods of non-uniformity response, an improved method based on single point calibration was proposed, which integrated the advance of single-point correction and two-point correction methods. The improved single-point method has the features of simple algorithm, high efficiency, good practical application, low work of measurement, and so on. The results of experiments show that the non-uniformity response of TDI CCD imaging system declines from 3.5% to 1.5% according to the images using the improved method of single point calibration. The maximum of non-uniformity responses among multiple outputs is less than 2.5% during the full response range. The improved method of single-point calibration can satisfy the requirements of TDI CCD image systems and be practical in engineering.

Reference (15)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return