Volume 44 Issue 1
Feb.  2015
Turn off MathJax
Article Contents

Han Qijin, Zhang Xuewen, Qiao Zhiyuan, Yang Lei, Pan Zhiqiang, Liu Li. Wide dynamic radiometric calibration of GF-1 PMS sensors using multi-test sites[J]. Infrared and Laser Engineering, 2015, 44(1): 127-133.
Citation: Han Qijin, Zhang Xuewen, Qiao Zhiyuan, Yang Lei, Pan Zhiqiang, Liu Li. Wide dynamic radiometric calibration of GF-1 PMS sensors using multi-test sites[J]. Infrared and Laser Engineering, 2015, 44(1): 127-133.

Wide dynamic radiometric calibration of GF-1 PMS sensors using multi-test sites

  • Received Date: 2014-05-14
  • Rev Recd Date: 2014-06-03
  • Publish Date: 2015-01-25
  • In order to overcome the limitations of conventional calibration method and realize high precision in-flight radiometric calibration of GF-1 PMS sensors, a new wide dynamic radiometric calibration method using multi-test sites was presented, and the uncertainty of this method was analyzed. Firstly, the wide dynamic radiometric calibration theory was introduced and the characteristics of test sites was described. Besides, the GF-1 satellite to field synchronous observing campaign with multi test sites was designed. Secondly, based on measured data and wide dynamic calibration model, the calibration of PMS sensors was finished. Finally, the uncertainty and feasibility of this calibration algorithmic were discussed. The radiometric properties of GF-1 PMS sensors have changed comparing with the prelaunch laboratory calibrated results, and the biggest change is close to 7.72%. And the uncertainty of wide dynamic radiometric calibration of PMS sensors based on multi-test sites is 5.35%. The obtained precision of calibration coefficients meets the requirements of remote sensing radiance's retrieval, and the method provides a reference for further calibration of high resolution satellite.
  • [1]
    [2] Liang Shunlin. Quantitative Remote Sensing of Land Surfaces[M]. London: John Wiley Sons Inc, 2004.
    [3] Xiong X X, William B. An overview of MODIS radiometric calibration and characteriztion [J]. Advances in Atmospheric Sciences, 2006, 23(1): 69-79.
    [4]
    [5] Dinguirard M, Slater P N. Calibration of space-multispectral imaging payloads: a review [J]. Remote Sensing of Environment, 1999, 68: 194-205.
    [6]
    [7]
    [8] Gao Hailiang, Gu Xingfa, Yu Tao, et al. The research overview on visible and near-infrared channels radiometric calibration of space borne optical remote sensors [J]. Remote Sensing Information, 2010, 4: 117-128. (in Chinese) 高海亮, 顾行发, 余涛, 等. 星载光学遥感器可见光近红外通道辐射定标研究进展[J]. 遥感信息, 2010, 4: 117-128.
    [9]
    [10] Han Qijin, Liu Li, Fu Qiaoyan, et al. The cross-calibration of GF-1 WFV and SJ-9A PMS sensors based on homogeneous land surface targets [J]. Acta Optical Sinica, 2014, 34(6): 0628003. (in Chinese)韩启金, 刘李, 傅俏燕, 等. 基于稳定场地再分析资料的多源遥感器替代定标[J]. 光学学报, 2014, 34(11): 1128002.
    [11]
    [12] Han Qijin, Fu Qiaoyan, Zhang Xuewen, et al. High-frequency radiometric calibration for wide field-of-view sensor of GF-1 satellite [J]. Optics and Precision Engineering, 2014, 22(7): 1707-1714. (in Chinese) 韩启金, 傅俏燕, 张学文, 等. 高分一号卫星宽视场成像仪的高频次辐射定标[J]. 光学精密工程, 2014, 22(7): 1707-1714.
    [13] Xing Hui, Zhao Huijie, Cheng Xuan, et al. Radiometric calibration of hyperspectral imaging spectrometer based on AOTF [J]. Infrared and Laser Engineering, 2009, 38 (2): 205-210. (in Chinese) 邢辉, 赵慧洁, 程宣, 等. AOTF 的高光谱成像光谱仪的辐射定标技术[J]. 红外与激光工程, 2009, 38(2): 205-210.
    [14]
    [15]
    [16] Han Qijin, Fu Qiaoyan, Pan Zhiqiang, et al. Absolute radiometric calibration and validation analysis of ZY-3 using artificial targets [J]. Infrared and Laser Engineering, 2013, 42(S1): 167-173. (in Chinese) 韩启金, 傅俏燕, 潘志强, 等. 资源三号卫星靶标法绝对辐射定标与验证分析[J]. 红外与激光工程, 2013, 42(S1): 167-173.
    [17]
    [18] Zheng X B, Wu H Y, Zhang J P, et al. High-accuracy primary and transfer standards for radiometric calibration [J]. Chinese Science Bulletin, 2000, 45(21): 2009-2013.
    [19] Gu Xingfa, Tian Guoliang, Yu Tao, et al. Radiometric Calibration Theory and Method of Space Optical Sensors[M]. Beijing: Science Press, 2013: 72-126. (in Chinese) 顾行发, 田国良, 余涛, 等. 航天光学遥感器辐射定标原理与方法[M]. 北京: 科学出版社, 2013: 72-126.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(703) PDF downloads(329) Cited by()

Related
Proportional views

Wide dynamic radiometric calibration of GF-1 PMS sensors using multi-test sites

  • 1. China Center for Resources Satellite Data and Application,Beijing 100094,China

Abstract: In order to overcome the limitations of conventional calibration method and realize high precision in-flight radiometric calibration of GF-1 PMS sensors, a new wide dynamic radiometric calibration method using multi-test sites was presented, and the uncertainty of this method was analyzed. Firstly, the wide dynamic radiometric calibration theory was introduced and the characteristics of test sites was described. Besides, the GF-1 satellite to field synchronous observing campaign with multi test sites was designed. Secondly, based on measured data and wide dynamic calibration model, the calibration of PMS sensors was finished. Finally, the uncertainty and feasibility of this calibration algorithmic were discussed. The radiometric properties of GF-1 PMS sensors have changed comparing with the prelaunch laboratory calibrated results, and the biggest change is close to 7.72%. And the uncertainty of wide dynamic radiometric calibration of PMS sensors based on multi-test sites is 5.35%. The obtained precision of calibration coefficients meets the requirements of remote sensing radiance's retrieval, and the method provides a reference for further calibration of high resolution satellite.

Reference (19)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return