Volume 44 Issue 3
Apr.  2015
Turn off MathJax
Article Contents

Guo Fenglei, Zhang Mingyue, Xiao Zheng, Li Xiangjun, Liu Jianjun. Refraction problems in continuous wave THz-CT[J]. Infrared and Laser Engineering, 2015, 44(3): 969-973.
Citation: Guo Fenglei, Zhang Mingyue, Xiao Zheng, Li Xiangjun, Liu Jianjun. Refraction problems in continuous wave THz-CT[J]. Infrared and Laser Engineering, 2015, 44(3): 969-973.

Refraction problems in continuous wave THz-CT

  • Received Date: 2014-07-05
  • Rev Recd Date: 2014-08-15
  • Terahertz CT setup was designed and constructed by backward wave Oscillator which has been used to perform computed tomography of 3D objects. However, the imaging quality is affected by strong refraction from materials with the refractive index greater than 1.5 in objects. At first, the cross section image of a teflon modal was reconstructed from the projection dataset by the filtered backprojection algorithm , then high refraction effects were analyzed. Finally, a human tooth sample was scanned and the cross section images were reconstructed to reveal its internal structures. However, the accuracy and resolution of the images were still limited owing to the high refraction effects. And the terahertz transmission depth in teeth was seriously affected by the thickness of enamel. The results in paper are helpful to improve the imaging quality of THz-CT and promote its applications especially in biomedical imaging of human bones like human tooth.
  • [1]
    [2] Kawase K, Ogawa Y, Watanabe Y, et al. No-destructive terahertz imaging of illicit drugs using spectral fingerprints[J]. Opt Express, 2003, 11(20): 2549-2554.
    [3] Hu B B, Nuss M C. Imaging with terahertz waves[J]. Optics Letters, 1995, 20(16): 1716-1718.
    [4]
    [5] Takayanagi J, Jinno H, Ichino S, et al. High resolution tim- o-flight terahertz tomography using a femtosecond fiber laser[J]. Optics Express, 2009, 17(9): 7533-7539.
    [6]
    [7] Ferguson B, Wang S, Gray D, et al. T-ray computed tomography[J]. Optics Letters, 2002, 27(15): 1312-1314.
    [8]
    [9]
    [10] Kindt J T, Schmuttenmaer C A. Fa-Infrared dielectric properties of polar l iquids probed by femtosecond terahertz pulse spectroscopy[J]. Phys Chem, 1996, 100(24): 10373-10379.
    [11]
    [12] Karpowicz N, Zhong H, Xu J, et al. Comparison between pulsed terahertz tim-domain imaging and continuous wave terahertz imaging [J]. Semicond Sci Technol, 2005, 20 (7): S293-299.
    [13]
    [14] Sunaguchi N, Sasaki Y, Maikusa N, et al. Dept-resolving THz imaging with tomosynthesis [J]. Optics Express, 2009, 17(12): 9558-9570.
    [15] Pearce J, Mittleman D M. Using terahertz pulses to study light scattering [J]. Physica B: Condensed Matter, 2003, 38 (1): 92-96.
    [16]
    [17] Meng Zhuo, Yao Hui, Liang Yan, et al. Measurement of the refractive index of human teeth by optical coherence tomography [J]. Journal of Biomedical Optics, 2009, 14(3): 034010.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(303) PDF downloads(187) Cited by()

Related
Proportional views

Refraction problems in continuous wave THz-CT

  • 1. College of Information Engineering,Center for THz Research,China Jiliang University,Hangzhou 310018,China;
  • 2. Naval Convalescent District,Hangzhou Sanatorium of Nanjing Military Command,Hangzhou 310002,China

Abstract: Terahertz CT setup was designed and constructed by backward wave Oscillator which has been used to perform computed tomography of 3D objects. However, the imaging quality is affected by strong refraction from materials with the refractive index greater than 1.5 in objects. At first, the cross section image of a teflon modal was reconstructed from the projection dataset by the filtered backprojection algorithm , then high refraction effects were analyzed. Finally, a human tooth sample was scanned and the cross section images were reconstructed to reveal its internal structures. However, the accuracy and resolution of the images were still limited owing to the high refraction effects. And the terahertz transmission depth in teeth was seriously affected by the thickness of enamel. The results in paper are helpful to improve the imaging quality of THz-CT and promote its applications especially in biomedical imaging of human bones like human tooth.

Reference (17)