Volume 44 Issue 6
Aug.  2015
Turn off MathJax
Article Contents

Bao Rima, Dong Chen, Lan Xingying, Feng Chengjing, Meng Qian, Zhao Kun. Content measurement of hydrocarbons in alkylate gasoline based on terahertz time-domain spectroscopy[J]. Infrared and Laser Engineering, 2015, 44(6): 1823-1826.
Citation: Bao Rima, Dong Chen, Lan Xingying, Feng Chengjing, Meng Qian, Zhao Kun. Content measurement of hydrocarbons in alkylate gasoline based on terahertz time-domain spectroscopy[J]. Infrared and Laser Engineering, 2015, 44(6): 1823-1826.

Content measurement of hydrocarbons in alkylate gasoline based on terahertz time-domain spectroscopy

  • Received Date: 2014-10-10
  • Rev Recd Date: 2014-11-15
  • Publish Date: 2015-06-25
  • In this work, terahertz time-domain spectroscopy(THz-TDS) was used to measure the content of hydrocarbons in alkylate gasoline as a new kind of non-destructive testing. 2,4,4-trimethyl-pentene(2,4,4-TMP), a representative kind of olefin, was mixed in alkylate gasoline. The spectral response of the samples containing different 2,4,4-TMP in terahertz band was analyzed. The results showed that amplitude of samples had a significant change in signals and varied linearly with content of 2,4,4-TMP changed. The curves, fitting by maximum and minimum values(amplitude) of spectra, were used to predict two unknown sample concentration. As a result, the error is less than 0.5%. Meanwhile, the absorption coefficient of samples were analyzed. The research indicates that THz -TDS technique is very suitable for detection of composition and content of hydrocarbons in gasoline.
  • [1]
    [2] Hu Yingmei. Advances in gasoline alkylates production technology[J]. Modern Chemical Industry, 2008, 28(10): 30-34. (in Chinese)
    [3] Zhu Xiuhua. Analysis of hydrocarbons in alkylate gasoline[J]. Chemical Analysis and Meterage, 2002, 11(3): 4-6. (in Chinese)
    [4]
    [5]
    [6] Yan Hugen, Li Xuesong, Chandra Bhupesh C, et al. Tunable infrared plasmonic devices using graphene/insulator stacks[J]. Nature Nanotechnology, 2012, 7(5): 330-334.
    [7]
    [8] Ji Jiangjun, Kong Depeng, Ma Tian, et al. Design and fabrication of cyclic-olefin copolymer based hollow-core microstructured terahertz fiber[J]. Infrared and Laser Engineering, 2014, 43(6): 1909-1913. (in Chinese)
    [9] Globus T, Woolard D, Crowe T W, et al. Terahertz Fourier transform characterization of biological materials in a liquid phase[J]. Journal of Physics D: Applied Physics, 2006, 39(15): 3405.
    [10]
    [11] Guo Lantao, Mu Kaijun, Deng Chao, et al. Terahertz spectroscopy and imaging [J]. Infrared and Laser Engineering, 2013, 42(1): 51-56. (in Chinese)
    [12]
    [13]
    [14] Leng Wenxiu, Ge Lina, Xu Shansen, et al. Pressure-dependent terahertz optical characterization of heptafluoropropane[J]. Chinese Physics B, 2014, 23(10): 107804.
    [15] Luo Jun, Gong Jinhui, Zhang Xinyu, et al. Transmission properties of continuous terahertz waves based on metamaterials[J]. Infrared and Laser Engineering, 2013, 42(7): 1743-1747. (in Chinese)
    [16]
    [17] Jin Wujun, Li Tao, Zhao Kun, et al. Monitoring the reaction between AlCl3 and o-xylene by using terahertz spectroscopy[J]. Chinese Physics B, 2013, 22(11): 118701.
    [18]
    [19] Dong Chen, Bao Rima, Zhao Kun, et al. Terahertz time-domain spectroscopy of a simulated pore structure to probe particle size and porosity of porous rock[J]. Chinese Physics B, 2014, 23(12): 127802.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(391) PDF downloads(183) Cited by()

Related
Proportional views

Content measurement of hydrocarbons in alkylate gasoline based on terahertz time-domain spectroscopy

  • 1. State Key Laboratory of Heavy Oil Processing,China University of Petroleum,Beijing 102249,China;
  • 2. Beijing Key Laboratory of Optical Detection Technology for Oil and Gas,China University of Petroleum,Beijing 102249,China;
  • 3. Key Laboratory of Oil and Gas Terahertz Spectroscopy and Photoelectric Detection,China Petroleum and Chemical Industry Federation (CPCIF),Beijing 100723,China

Abstract: In this work, terahertz time-domain spectroscopy(THz-TDS) was used to measure the content of hydrocarbons in alkylate gasoline as a new kind of non-destructive testing. 2,4,4-trimethyl-pentene(2,4,4-TMP), a representative kind of olefin, was mixed in alkylate gasoline. The spectral response of the samples containing different 2,4,4-TMP in terahertz band was analyzed. The results showed that amplitude of samples had a significant change in signals and varied linearly with content of 2,4,4-TMP changed. The curves, fitting by maximum and minimum values(amplitude) of spectra, were used to predict two unknown sample concentration. As a result, the error is less than 0.5%. Meanwhile, the absorption coefficient of samples were analyzed. The research indicates that THz -TDS technique is very suitable for detection of composition and content of hydrocarbons in gasoline.

Reference (19)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return