Wang Lan, Sun Bo, Long Changyu, Zou Jian, Zhu Jigui. A novel method for calibrating intrinsic parameters of linear array cameras based on collinear feature points[J]. Infrared and Laser Engineering, 2015, 44(6): 1878-1883.
Citation: Wang Lan, Sun Bo, Long Changyu, Zou Jian, Zhu Jigui. A novel method for calibrating intrinsic parameters of linear array cameras based on collinear feature points[J]. Infrared and Laser Engineering, 2015, 44(6): 1878-1883.

A novel method for calibrating intrinsic parameters of linear array cameras based on collinear feature points

  • Received Date: 2014-10-12
  • Rev Recd Date: 2014-11-15
  • Publish Date: 2015-06-25
  • A novel method was proposed that can be used for determining intrinsic parameters of linear array cameras based on collinear calibration feature points. All calibration feature points were on the view plane of the linear array camera. Firstly, during the camera calibration the feature point was captured by the camera one by one, the corresponding image point and the spatial feature point were obtained directly, which solved the matching problem of the spatial feature point and image point. Secondly, a mathematical model was established to obtain the imaging model of the linear array camera, then use the simultaneous imaging models of multiple locations was used to calculate the camera intrinsic parameters; Finally, the impacts on the calibration result were analyzed and experimented. Result reveals that the proposed linear array camera calibration method is not only convenient and flexible, but also sophisticated calibration pattern is not required, and a lot of calibration points are obtained which improving the accuracy and stability of the line scan camera calibration. The root mean square error of re-projected points is less than 0.37 pixel.
  • [1] Lim M S, Lim J. Visual measurement of pile movements for the foundation work using a high-speed line-scan camera[J]. Pattern Recognition, 2008, 41(6): 2025-2033.
    [2]
    [3] Petty R S, Robinson M, Evans J P O. 3D measurement using rotating line-scan sensors[J]. Measurement Science and Technology, 1998, 9(3): 339.
    [4]
    [5] Kataoka K, Osawa T, Ozawa S, et al. 3D building facade model reconstruction using parallel images acquired by line scan cameras[C]//IEEE International Conference on Image Processing, 2005, 1: I-1009-12.
    [6]
    [7] Tsai R Y. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses[J]. Robotics and Automation, IEEE Journal of, 1987, 3(4): 323-344.
    [8]
    [9]
    [10] Liu Weiyi, Jia Jiqiang, Ding Yalin, et al. Measurement error impact on intrinsic parameters calibration in precise angle measurement method[J]. Infrared and Laser Engineering, 2009, 38(4): 705-709. (in Chinese) 刘伟毅, 贾继强, 丁亚林, 等. 精密测角法中测量误差对内方位元素标定的影响[J]. 红外与激光工程, 2009, 38(4): 705-709.
    [11]
    [12] Niu Haitao, Zhao Xunjie. New method of camera calibration based on checkerboard[J]. Infrared and Laser Engineering, 2011, 40(1): 133-137. (in Chinese) 牛海涛, 赵勋杰. 采用棋盘格模板的摄像机标定新方法[J]. 红外与激光工程, 2011, 40(1): 133-137.
    [13] Zhang Dan, Duan Jin, Gu Lingjia, et al. Method of camera calibration based on image processing[J]. Infrared and Laser Engineering, 2007, 36(S1): 561-565. (in Chinese) 张丹, 段锦, 顾玲嘉, 等. 基于图像的模拟相机标定方法的研究[J]. 红外与激光工程, 2007, 36(S1): 561-565.
    [14]
    [15]
    [16] Horaud R, Mohr R, Lorecki B. On single scanline camera calibration[J]. Robotics and Automation, IEEE Transactions On, 1993, 9(1): 71-75.
    [17]
    [18] Luna C A, Mazo M, Lzaro J L, et al. Calibration of line-scan cameras[J]. Instrumentation and Measurement, IEEE Transactions on, 2010, 59(8): 2185-2190.
    [19]
    [20] Drarni J, Roy S, Sturm P. Plane-based calibration for linear cameras[J]. International Journal of Computer Vision, 2011, 91(2): 146-156.
    [21] Hui B, Wen G, Zhao Z, et al. Line-scan camera calibration in close-range photogrammetry[J]. Optical Engineering, 2012, 51(5): 053602-1-053602-12.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(429) PDF downloads(320) Cited by()

Related
Proportional views

A novel method for calibrating intrinsic parameters of linear array cameras based on collinear feature points

  • 1. State Key Laboratory of Precision Measuring Technology and Instruments,Tianjin University,Tianjin 300072,China;
  • 2. Optics and Teaching Research Section,Ordnance Engineering College,Shijiazhuang 050003,China

Abstract: A novel method was proposed that can be used for determining intrinsic parameters of linear array cameras based on collinear calibration feature points. All calibration feature points were on the view plane of the linear array camera. Firstly, during the camera calibration the feature point was captured by the camera one by one, the corresponding image point and the spatial feature point were obtained directly, which solved the matching problem of the spatial feature point and image point. Secondly, a mathematical model was established to obtain the imaging model of the linear array camera, then use the simultaneous imaging models of multiple locations was used to calculate the camera intrinsic parameters; Finally, the impacts on the calibration result were analyzed and experimented. Result reveals that the proposed linear array camera calibration method is not only convenient and flexible, but also sophisticated calibration pattern is not required, and a lot of calibration points are obtained which improving the accuracy and stability of the line scan camera calibration. The root mean square error of re-projected points is less than 0.37 pixel.

Reference (21)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return