Volume 44 Issue 8
Sep.  2015
Turn off MathJax
Article Contents

Yang Lei, Fu Qiaoyan, Pan Zhiqiang, Zhang Xuewen, Han Qijin, Liu Li. Research of radiometric cross-calibration about GF-1 satellite sensors[J]. Infrared and Laser Engineering, 2015, 44(8): 2456-2460.
Citation: Yang Lei, Fu Qiaoyan, Pan Zhiqiang, Zhang Xuewen, Han Qijin, Liu Li. Research of radiometric cross-calibration about GF-1 satellite sensors[J]. Infrared and Laser Engineering, 2015, 44(8): 2456-2460.

Research of radiometric cross-calibration about GF-1 satellite sensors

  • Received Date: 2014-12-20
  • Rev Recd Date: 2015-01-22
  • Publish Date: 2015-08-25
  • This paper is about the radiometric cross-calibration method of GF-1 image with landsat8-OLI data. First the cross-calibration was implemented using the night deep sea imaging to obtain the bias of GF-1 cross-calibration coefficient. Then eight times images of two sensors passing through the target place were selected to obtain the gains of the GF-1 cross-calibration coefficient. The correlation between the radiance value calculated by the cross-calibration coefficient and the synchronous observations of the Landsat8 radiance value is above 95%. The accuracy relative errors of the 4 bands are 4.25%, 6.21%, 5.83% and 5.66% respectively. The results show that the calibration coefficients obtained from the method have a similar precision as Landsat8-OLI. The calibration coefficients can satisfy the quantitative applications of GF-1 data.
  • [1] Han Qijin, Fu Qiaoyan, Pan Zhiqiang, et al. Absolute radiometric calibration and validation analysis of ZY-3 using artificial targets[J]. Infrared and laser Engineering, 2013, 42(S1): 167-173. (in Chinese)韩启金, 傅俏燕, 潘志强, 等. 资源三号卫星靶标法决对辐射定标与验证分析[J]. 红外与激光工程, 2013, 42(S1): 167-173.
    [2]
    [3]
    [4] Teillet P M, Baker J L. Radiometric cross-calibration of the Landsat-7 ETM+ and Landsat-5 TM sensors based on tandem data sets[J]. Remote Sensing of Environment, 2001, 78: 39-54
    [5]
    [6] Sun Ke, Fu Qiaoyan, Qi Xueyong, et al. Radiometric cross-calibration of thermal infrared channel of IRS sensor on HJ-1B satellite[J]. Infrared and laser Engineering, 2010, 39(7): 785-790. (in Chinese)孙珂, 傅俏燕, 亓学勇, 等. HJ-1B卫星IRS传感器热红外通道交叉定标[J]. 红外与激光工程, 2010, 39(7): 785-790.
    [7] Xu Na, Hu Xueqing, Chen Lin, et al. Cross-calibration of FY-2E/VISSR infrared window and water vapor channels with TERRA/MODIS[J]. Journal of Infrared and Millimeter Waves, 2012, 31(4): 319-384. (in Chinese)徐娜, 胡秀清, 陈林, 等. 利用MODIS对FY-2E/VISSR红外窗区和水汽通道的交叉决对辐射定标[J]. 红外与毫米波学报, 2012, 31(4): 319-384.
    [8]
    [9] Zhang Yong, Gu Xingfa, Yu Tao, et al. Radiometric cross-calibration of cbers-02 IRMSS thermal channel[J]. Journal of Infrared and Millimeter Waves, 2006, 25(4): 261-266. (in Chinese)张勇, 顾行发, 余涛, 等. 中巴地球资源卫星热红外通道的交叉辐射定标[J]. 红外与毫米波学报, 2006, 25(4): 261-266.
    [10]
    [11] Han Qijin, Zhang Xuewen, Qiao Zhiyuan, et al. Wide dynamic radiometric calibration of GF-1 PMS sensors using multi-test sites[J]. Infrared and laser Engineering, 2015, 44(1): 127-133. (in Chinese)韩启金, 张学文, 乔志远, 等. 高分一号卫星PMS相机多场地宽动态辐射定标 [J]. 红外与激光工程, 2015, 44(1): 127-133.
    [12]
    [13] U.S. Geological Survey(USGS)/National Aeronautics and Space Administration(NASA). LDCU CAL/VAL algorithm description document[R]. 2013.
    [14]
    [15] Yang Zhongdong, Gu Songyan, Qiu Hong, et al. Research on the algorithm of cross calibration about IRMSS abord CBERS-01[J]. Infrared and laser Engineering, 2003, 22(4): 281-285. (in Chinese)杨忠东, 谷岩松, 邱红, 等. 中巴地球资源一号卫星红外多光谱扫描仪交叉定标方法研究[J]. 红外与激光工程, 2003, 22(4): 281-285.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(364) PDF downloads(169) Cited by()

Related
Proportional views

Research of radiometric cross-calibration about GF-1 satellite sensors

  • 1. China Center for Resources Satellite Data and Application,Beijing 100094,China

Abstract: This paper is about the radiometric cross-calibration method of GF-1 image with landsat8-OLI data. First the cross-calibration was implemented using the night deep sea imaging to obtain the bias of GF-1 cross-calibration coefficient. Then eight times images of two sensors passing through the target place were selected to obtain the gains of the GF-1 cross-calibration coefficient. The correlation between the radiance value calculated by the cross-calibration coefficient and the synchronous observations of the Landsat8 radiance value is above 95%. The accuracy relative errors of the 4 bands are 4.25%, 6.21%, 5.83% and 5.66% respectively. The results show that the calibration coefficients obtained from the method have a similar precision as Landsat8-OLI. The calibration coefficients can satisfy the quantitative applications of GF-1 data.

Reference (15)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return