Cui Shanshan, Meng Binghuan, Qiu Zhenwei, Hong Jin, Zou Peng. Study of synchronous sampling method for the relative spectral response of CCD[J]. Infrared and Laser Engineering, 2015, 44(11): 3397-3401.
Citation: Cui Shanshan, Meng Binghuan, Qiu Zhenwei, Hong Jin, Zou Peng. Study of synchronous sampling method for the relative spectral response of CCD[J]. Infrared and Laser Engineering, 2015, 44(11): 3397-3401.

Study of synchronous sampling method for the relative spectral response of CCD

  • Received Date: 2015-03-07
  • Rev Recd Date: 2015-04-12
  • Publish Date: 2015-11-25
  • Continuously tunable monochromatic light source system is a dedicated test system for radiation parameter quantitatively of CCD, it can be used to measure the relative spectral response of CCD. Compared with the conventional test apparatus, the system is possible to achieve spectral resolution of 1 nm due to the use of the high-power xenon lamp. However, the lamp introduces instability problems. The conventional time-sharing measurement method can lead to poor measurement uncertainty, and can not meet the development needs of high-precision remote sensing instrument, and then a synchronous sampling method was proposed. Combining with the comprehender of the CCD calibration theoretical model, the measurement uncertainty of two methods was analyzed. The result shows that the synchronous sampling uncertainty is better than 1.03%, which increases 43% compared with the traditional time-sharing measurement method. Otherwise, it also has a contrast testing using the two methods. As a result, the relative spectral response curve of the CCD received by the synchronous sampling method is more flat, and the standard deviation is more low, which verify the correctness of the conclusions of the analysis.
  • [1] Lesser M P, McCarthy B L. Quantum efficiency characterization of scientific CCDs[C]//SPIE, 1996, 2654: 278-286.
    [2] Amico P, Bohm T. ESO's new CCD testbench [J]. Exp Astronomym, 1998, (8): 1-8.
    [3] Groom D E, Bebek C J, Fabricius M, et al. Quantum efficiency characterization of LBNL CCD's [C]//SPIE, 2006, 6068: 101-111.
    [4] Steckert J. Design, implementation and setup of an automated quantum efficiency measurement system for charge-coupled devices [D]. Berkeley: Diplom Thesis, 2005.
    [5] Shao Xiaopeng, Wang Yang, Gao Peng, et al. Measurement method and setup of the quantum efficiency for charge coupled devices[J]. Infrared and Laser Engineering, 2013, 42(S1): 103-106. (in Chinese)
    [6] Emva Standard 1288: Standard for characterization of image sensors and cameras[S]. European Machine Vision Association, 2010.
    [7] Zhou Lei, Zhang Junping, Zheng Xiaobing. Radiation flux calibration performed by a single chip detector[J]. Opto-Electronic Engineering, 2005, 32(6): 59-62. (in Chinese)
    [8] Ya Feng, Zhou Yue, Zhang Mingchao, et al. Test equipment for relative spectral response of CCD [J]. Spectroscopy and Spectral Analys, 2005, 32(6): 59-62. (in Chinese)
    [9] Xu Qiuyun, Zheng Xiaobing, Li Jianjun, et al. Development of laser illuminated integrating sphere source [J]. Optics and Precision Engineering, 2009, 17(4): 738-744. (in Chinese)
    [10] Wang Yong, Lv Suhong, Ma Fei, et al. Non synchronous sampling error correction system analysis [J]. Henan Electric Power, 2005, 3: 23-25. (in Chinese)
    [11] Holst G C. CCD Arrays, Cameras, and Displays [M]. USA: SPIE Optical Engineering Press, 1998.
    [12] Li Yunfei, Li Minjie, Si Guoliang, et al. Noise analyzing and processing of TDI-CCD image sensor[J]. Optics and Precision Engineering, 2007, 15(8): 1196-1202. (in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(386) PDF downloads(157) Cited by()

Related
Proportional views

Study of synchronous sampling method for the relative spectral response of CCD

  • 1. Key Laboratory of Optical Calibration and Characterization,Anhui Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,Hefei 230031,China

Abstract: Continuously tunable monochromatic light source system is a dedicated test system for radiation parameter quantitatively of CCD, it can be used to measure the relative spectral response of CCD. Compared with the conventional test apparatus, the system is possible to achieve spectral resolution of 1 nm due to the use of the high-power xenon lamp. However, the lamp introduces instability problems. The conventional time-sharing measurement method can lead to poor measurement uncertainty, and can not meet the development needs of high-precision remote sensing instrument, and then a synchronous sampling method was proposed. Combining with the comprehender of the CCD calibration theoretical model, the measurement uncertainty of two methods was analyzed. The result shows that the synchronous sampling uncertainty is better than 1.03%, which increases 43% compared with the traditional time-sharing measurement method. Otherwise, it also has a contrast testing using the two methods. As a result, the relative spectral response curve of the CCD received by the synchronous sampling method is more flat, and the standard deviation is more low, which verify the correctness of the conclusions of the analysis.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return