Volume 43 Issue 1
Jan.  2014
Turn off MathJax
Article Contents

Jiang Shichen, Hu Bingting, Fu Xin, Kang Aofeng, Dong Yaohai. Experiment on thermoelectric coolers’ performance using for heat dissipation of satellite CCDs[J]. Infrared and Laser Engineering, 2014, 43(1): 123-128.
Citation: Jiang Shichen, Hu Bingting, Fu Xin, Kang Aofeng, Dong Yaohai. Experiment on thermoelectric coolers’ performance using for heat dissipation of satellite CCDs[J]. Infrared and Laser Engineering, 2014, 43(1): 123-128.

Experiment on thermoelectric coolers’ performance using for heat dissipation of satellite CCDs

  • Received Date: 2013-05-10
  • Rev Recd Date: 2013-06-25
  • Publish Date: 2014-01-25
  • Because of high power and low temperature level requirement, thermoelectric coolers were used for heat dissipation of CCDs on a geostationary earth orbit satellite camera. Experimental setup for evaluating thermoelectric coolers' performance was designed. Domestic and oversea thermoelectric coolers were tested in atmosphere and vacuum respectively. Effects of installation, environment pressure, input power and heat load on the temperature difference of thermoelectric coolers' hot and cold faces were obtained experimentally. The experimental results showed that, for present CCDs' heat load on a geostationary orbit satellite, the maximum temperature difference between cold and hot faces was 45.8℃, which satisfied the requirement for running at low temperature level.
  • [1]
    [2] Pei Nianqiang, Guo Kaihua, Liu Jie. Applied calculation of peltier cooler in one new LHP [J]. Chinese Journal of Low Temperature Physics, 2007, 29(1): 42-45. (in Chinese) 裴念强, 郭开华,刘杰. 半导体制冷在新型环路热管的应用 计算[J]. 低温物理学报, 2007, 29(1): 42-45.
    [3] Shen Limei, Chen Huanxin, Zhang Wei, et al. Analysis of the crucial factors affecting the performance of thermoelectric cooling [J]. Infrared and Laser Engineering, 2011, 40(10): 1866-1872. (in Chinese)申利梅, 陈焕新, 张威, 等. 影响热电制冷性能的关键因素 及其分析[J]. 红外与激光工程, 2011, 40(10): 1866-1872.
    [4]
    [5]
    [6] Zhang Jiancheng. Study of heat transfer about heat pipe type cooler of semiconductor refrigerating element [J]. Southeast University, 2000, 30(5): 38-41. (in Chinese) 张建成. 半导体制冷的热管式散热器传热研究[J]. 东南大 学学报, 2000, 30(5): 38-41.
    [7]
    [8] Li Mingshan, Zhang Wenping, Wang Shiyu, et al. Opitmal thermal dissipation of LD in high power DPL under high temperature environment [J]. Infrared and Laser Engineering, 2008, 37(2); 221-225. (in Chinese) 李明山, 张文平, 王石语, 等. 高温环境下大功率DPL 的LD 最佳散热效果[J]. 红外与激光工程, 2008, 37(2): 221-225.
    [9] Lian Xinhao, Yan Yinxue. Thermal design of focal plane assembly on space-borne camera based on thermo-electric cooling technology [J]. Spacecraft Recovery Remote Sensing, 2011.32(3): 43-50. (in Chinese) 连新昊, 颜吟雪. 基于热电制冷技术的某星载相机焦面组 件热设计[J]. 航天返回与遥感, 2011, 32(3): 43-50.
    [10]
    [11] Baggett S M, Hill R J, Kimble R A. The wide-field camera 3 detectors[C]//SPIE, 2008, 7021: 70211Q-1-11.
    [12]
    [13]
    [14] Marc D Rafal. Thermal design for the advanced camera for surveys[C]//SPIE, 1998, 3356: 301-307.
    [15] Gregory B Johnson. Thermal management for CCD performance on the advanced camera for surveys(ACS)[C] // SPIE, 1998, 3356: 284-291.
    [16]
    [17]
    [18] David E Neuberger, James C Bremer, Margo Mehoke. Advanced geosyncronous studies imager thermal design[C] // SPIE, 1999, 3750: 68-78.
    [19] Zhang Jianzhong, Wang Zesheng. Reliability design of the thermoelectric cooler [C]//Proceedings of The 8th Conference on Reliability, Chinese Institute of Electronics, 1996: 26-31.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(450) PDF downloads(166) Cited by()

Related
Proportional views

Experiment on thermoelectric coolers’ performance using for heat dissipation of satellite CCDs

  • 1. Laboratory of Space Mechanical and Thermal Integrative Technology,Shanghai Institute of Satellite Engineering,Shanghai200240,China;
  • 2. Shanghai Academy of Spaceflight Technology,Shanghai 201109,China

Abstract: Because of high power and low temperature level requirement, thermoelectric coolers were used for heat dissipation of CCDs on a geostationary earth orbit satellite camera. Experimental setup for evaluating thermoelectric coolers' performance was designed. Domestic and oversea thermoelectric coolers were tested in atmosphere and vacuum respectively. Effects of installation, environment pressure, input power and heat load on the temperature difference of thermoelectric coolers' hot and cold faces were obtained experimentally. The experimental results showed that, for present CCDs' heat load on a geostationary orbit satellite, the maximum temperature difference between cold and hot faces was 45.8℃, which satisfied the requirement for running at low temperature level.

Reference (19)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return