  • In order to increase the angular position measurement accuracy and improve structure design of a precise turntable, the angular position measurement precision of its azimuth shafting was detected. The error included axial error, encode error and other errors. Fourier harmonic analysis was adopted in data processing. Harmonic waves with different orders were used to fit the data, low order harmonic waves were removed, which could increase the position measure accuracy. Meanwhile, the error sources had been found. The error look up table could be used to correct the measure data afterward. As the result shows, the value of angular position measurement error after corrected is 1/4 of the value before corrected, the amplitude is about 0.8, the angular position measurement accuracy has been increased a lot. A look up table was built to correct post -measurement data; the error sources were found, which will help to improve the shafting structure.
  • [1] Feng Dongyan, Gao Yunguo, Zhang Wenbao. Elimination of shafting errors in photoelectrical theodolites with standard- bearings[J]. Optics and Precision Engineering, 2011, 19(3): 605-611. (in Chinese)
    [2]
    [3]
    [4] Du Junfeng, Li Zhengzhou. Analysis of the axial accuracy of the GD -220 photoelectric theodolite [J]. Optics Precission Engineer, 2002, 10(4): 416-419 (in Chinese)
    [5] Wang Tao, Zhu Mingchao, Yin Shengli, et al. Analysis of LOS pointing error derived from precision of shafting in stabilition mechnasm [J]. Infrared and Laser Engineering, 2011, 40 (11): 2266-2269. (in Chinese)
    [6]
    [7] Mao Yingtai. Error Theory and Precision Analysis [M]. Beijing: National Defence Industry Press, 1982. (in Chinese)
    [8]
    [9]
    [10] Gao Fuhui. Fourier harmonic analysis method for axial system wobbling of the largescale theodolite [J]. Opto-Electronic Engineering, 1998, 5(5): 1-15. (in Chinese)
    [11] Zhang Ning, Shen Xiangheng, Yang Liang, et al. Evaluation of tracking performance of photoelectric theodolite by using harmonic property of dynamic target [J]. Optics Precision Engineer, 2010, 18(6): 1286-1294. (in Chinese)
    [12]
    [13]
    [14] Xia Xintao, Ma Wei, Jie Tancheng, et al. Rolling Bearings Manufacturing Technology [M]. Beijing: China Machine Press, 2007. (in Chinese)
    [15] Zhao Yongzhi, Zhang Jingxu, Wu Xiaoxia, et al. Modification of altitude axis errors for 1m aperture telescopes [J]. Optics Precision Engineer, 2009, 17(10): 2401-2405. (in Chinese)
    [16]
    [17] Li Hui. New shafting error simulating method of photoelectric theodolite [J]. Infrared and Laser Engineering, 2008, 37(2): 334-337. (in Chinese)
    [18]
    [19] Xu Zhaodong, Chen Songcan, Li Xin. Analysis and improvement of dynamic accuracy in stabilizing platform system [J]. Infrared and Laser Engineering, 2006, 35: 454-458. (in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(340) PDF downloads(194) Cited by()

Related
Proportional views

Harmonic analysis application in accuracy improvement of precise turntable

  • 1. Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China;
  • 2. University of Chinese Academy of Sciences,Beijing 100049,China

Abstract: In order to increase the angular position measurement accuracy and improve structure design of a precise turntable, the angular position measurement precision of its azimuth shafting was detected. The error included axial error, encode error and other errors. Fourier harmonic analysis was adopted in data processing. Harmonic waves with different orders were used to fit the data, low order harmonic waves were removed, which could increase the position measure accuracy. Meanwhile, the error sources had been found. The error look up table could be used to correct the measure data afterward. As the result shows, the value of angular position measurement error after corrected is 1/4 of the value before corrected, the amplitude is about 0.8, the angular position measurement accuracy has been increased a lot. A look up table was built to correct post -measurement data; the error sources were found, which will help to improve the shafting structure.

Reference (19)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return