Cause of varying of theodolite orientation error and its solution

  • Received Date: 2012-07-05
  • Rev Recd Date: 2012-08-03
  • Publish Date: 2013-03-25
  • As the systematic error of the optoelectronic theodolite, the orientation error of the azimuth shafting encoder can be numbered and corrected before measuring. But the orientation error, as the systematic error, can constantly vary randomly in the course of work and inevitably make great influence on the measuring accuracy. It is believed that the gap between the joint lever and the switch port, when the leveling gear and the foundation bed are attached to each other, is the cause of error varying. On the basis of analyzing the previous solutions, the mechanical construction model combining the leveling gear and anti-twisting thin film was proposed, and it was found out that within the range of angle 7', both the bending stress and shearing stress of anti-twisting thin film were admissible stresses between the internal circle and the external circle of the anti-twisting thin film. The corner was smaller than 1of the encoder in precision. Thus the problem of azimuth axis angular adjustment was solved and it was assured that no orientation error occurs when it is under the moment of 4 000 Nm. Practice has shown that the approach is effective in solving the orientation error varying.
  • [1] Zhao Xueyan,Li Yingchun. Optical Measurement in Shooting Range [M]. Beijing: Institate of Command and Technology, 2001. (in Chinese)
    [2]
    [3] Paul R Yoder Jr. Opto-Mechanical Systems Design [M]. Beijing: China Machine Press, 2008. (in Chinese)
    [4]
    [5] Zhao Yongzhi, Zhang Jingxu, Wu Xiaoxia, et al. Modification of altitude axis errors for 1m aperture telescopes [J]. Optics and Precision Engineering, 2009, 17(10): 2401-2405.
    [6]
    [7]
    [8] Du Junfeng. Design of the wedge leveler [J]. Optics and Precision Engineering, 2003, 11(3): 301-304. (in Chinese)
    [9] Wang Tao, Zhu Mingchao, Yan Shengli. Analysis of LOS pointing error derived from precision of shafting in stabilization mechanism[J]. Infrared and Laser Engineering, 2011, 40(11): 2265-2269. (in Chinese)
    [10]
    [11] Yang Zhen, Li Guangyun, He Lei. Measurement methods and precision analysis of optical collimation [J]. Infrared and Laser Engineering, 2011, 40(2): 282-286. (in Chinese)
    [12]
    [13] Zhou Xiaoyao, Fan Dapeng, Zhang Zhiyong, et al. Analysis and design of multi-loop IMC controller for electro-optical serve control systems [J]. Infrared and Laser Engineering, 2011, 40(10): 2020-2027. (in Chinese)
    [14]
    [15] Liu Hongwen. Mechanics of Materials [M]. Beijing: Higher Education Press, 2004. (in Chinese)
    [16]
    [17] Gao Fuhui. Analysis for torsion distortion of an anti-twisting thin film[J]. Opto-Electronic Engineering, 1999, 26(4): 1-5. (in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(437) PDF downloads(163) Cited by()

Related
Proportional views

Cause of varying of theodolite orientation error and its solution

  • 1. Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China;
  • 2. No.703 Research Institute of China Shipbuilding Heavy Industry Corporation,Harbin 150078,China

Abstract: As the systematic error of the optoelectronic theodolite, the orientation error of the azimuth shafting encoder can be numbered and corrected before measuring. But the orientation error, as the systematic error, can constantly vary randomly in the course of work and inevitably make great influence on the measuring accuracy. It is believed that the gap between the joint lever and the switch port, when the leveling gear and the foundation bed are attached to each other, is the cause of error varying. On the basis of analyzing the previous solutions, the mechanical construction model combining the leveling gear and anti-twisting thin film was proposed, and it was found out that within the range of angle 7', both the bending stress and shearing stress of anti-twisting thin film were admissible stresses between the internal circle and the external circle of the anti-twisting thin film. The corner was smaller than 1of the encoder in precision. Thus the problem of azimuth axis angular adjustment was solved and it was assured that no orientation error occurs when it is under the moment of 4 000 Nm. Practice has shown that the approach is effective in solving the orientation error varying.