Volume 42 Issue 1
Feb.  2014
Turn off MathJax
Article Contents

Tan Jianyao, Ren Yu, Tan Yong, Zheng Feng, Hu Xinyue, Shi Jing, Cai Hongxing. Impact of the rotatory property of TeO2 crystal on its spectral characteristics[J]. Infrared and Laser Engineering, 2013, 42(1): 195-199.
Citation: Tan Jianyao, Ren Yu, Tan Yong, Zheng Feng, Hu Xinyue, Shi Jing, Cai Hongxing. Impact of the rotatory property of TeO2 crystal on its spectral characteristics[J]. Infrared and Laser Engineering, 2013, 42(1): 195-199.

Impact of the rotatory property of TeO2 crystal on its spectral characteristics

  • Received Date: 2012-05-22
  • Rev Recd Date: 2012-06-19
  • Publish Date: 2013-01-25
  • TeO2 is the main imaging crystal of acousto-optic tunable filter. There are chromatic aberration and drift in the crystal itself while the spectroscopic imaging. In this paper, based on the fundamental theory, the impact of TeO2 crystal optical activity to dichroism as the acousto-optic tunable filter was researched and its basic parameters were optimized. The I.C.Chang theoretical system and the P.A.Gass modified theoretical system were compared and analyzed. The results show that the two theoretical systems are quite different when the relationship of ultrasonic frequency coordination is calculated results in the infrared. Assuming that it was caused by the ignored the rotatory property of crystal of I.C.Chang theory, the design method of acousto-optic tunable filter based on P.A.Gass theory is applicable to infrared. The influence of rotatory property on the spectroradiometric property was smaller when the incident polar angle less than 30. Through comparative analysis research, incident polar angle of design should be less than 54.7 , which can maintain higher figure of merit of sound and light and a lower level of the ultrasonic frequency; in the infrared, the incident polar angle of the design should be less than 39.2 , between two frequency coordination deviation f is smaller.
  • [1]
    [2] Wan Feng, Li Xiaoxia, Sun Zhendong, et al. Development of an infrared on line spectrum measuring system with AOTF as the dispersion element[J]. PiezoelectricsAcoust Optics ICS, 2003, 25(1): 43-45. (in Chinese)
    [3] 万峰, 李小霞, 孙振东, 等. 以AOTF为核心的在线光谱测量系统的研制[J]. 压电与声光, 2003, 25(1): 43-45.
    [4] Harris S E, Wallace R W. Acousto-optic tunable filter[J]. Journal of the Optical Society of America, 1969, 59(6):744-747.
    [5]
    [6] Chang I C. Development of an infrared tunable acousto-optic filter[C]//SPIE, 1978, 0131: 2-10.
    [7]
    [8] Khoshnevisan M, Sovero E. Development of a cryogenic infrared acousto-optic tunable spectral filter[C]//SPIE, 1980, 245: 65-68.
    [9]
    [10] Weng Cuncheng. Method to improve the quality of acousto-optic imaging using an ultrashort and focused ultrasound pulse[J]. Applied Physics Letters, 2007, 90(12): 121108-28.
    [11]
    [12] Tran C D. Development and analytical application of multispectral imaging techniques: an overview [J]. Fresenius Journal of Analytical Chemistry, 1997, 369(3-4): 313-319.
    [13] Sun Zhendong, Wan Feng, Zhao Yuchun, et al. Development of the new infrared monochromatic system with AOTF technigue[J]. Optical Technique, 2002, 28(1): 36-37. (in Chinese)
    [14]
    [15] Gass P A, Sambler J R. Accurate design of a noncollinear acousto-optic tunable fitler[J]. Opt Letter, 1991, 16(6): 429-431.
    [16]
    [17]
    [18] Xing Hui, Zhao Huij+ie, Cheng Xuan, et al. Radiometric calibration of hyperspectral imaging spectrometer based on AOTF[J]. Infrared and Laser Engineering, 2009, 38(2): 205-210. (in Chinese)
    [19] Yu Guiying, Yao Shuai, Guo Tiantai, et al. Optimized design of AOTF mid-IR spectrometer based on Tracepro[J]. Infrared and Laser Engineering, 2008, 37(s): 441-444. (in Chinese)
    [20] 孙振东, 万峰, 赵玉春, 等. 采用AOTF技术的新型红外单色系统的研制[J]. 光学技术, 2002, 28(1): 36-37.
    [21]
    [22]
    [23]
    [24] 邢辉, 赵慧洁, 程宣, 等. AOTF的高光谱成像光谱仪的辐射定标技术[J]. 红外与激光工程, 2009, 38(2): 205-210.
    [25]
    [26]
    [27] 余桂英, 姚帅, 郭天太, 等. 基于 TracePro的AOTF中红外光谱仪的优化设计[J]. 红外与激光工程, 2008, 37(s): 441-444.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(306) PDF downloads(268) Cited by()

Related
Proportional views

Impact of the rotatory property of TeO2 crystal on its spectral characteristics

  • 1. College of Science,Changchun University of Science and Technology,Changchun 130022,China;
  • 2. International Joint Research Center for Nanophotonis and Biophotnics,Changchun University of Science and Technology,Changchun 130022,China

Abstract: TeO2 is the main imaging crystal of acousto-optic tunable filter. There are chromatic aberration and drift in the crystal itself while the spectroscopic imaging. In this paper, based on the fundamental theory, the impact of TeO2 crystal optical activity to dichroism as the acousto-optic tunable filter was researched and its basic parameters were optimized. The I.C.Chang theoretical system and the P.A.Gass modified theoretical system were compared and analyzed. The results show that the two theoretical systems are quite different when the relationship of ultrasonic frequency coordination is calculated results in the infrared. Assuming that it was caused by the ignored the rotatory property of crystal of I.C.Chang theory, the design method of acousto-optic tunable filter based on P.A.Gass theory is applicable to infrared. The influence of rotatory property on the spectroradiometric property was smaller when the incident polar angle less than 30. Through comparative analysis research, incident polar angle of design should be less than 54.7 , which can maintain higher figure of merit of sound and light and a lower level of the ultrasonic frequency; in the infrared, the incident polar angle of the design should be less than 39.2 , between two frequency coordination deviation f is smaller.

Reference (27)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return