Wang Yongpeng, Luo Jia, Bai Jian, Liang Yiyong. Analysis on mirrors installation error of high-accuracy long focal length measurement system[J]. Infrared and Laser Engineering, 2014, 43(2): 562-568.
Citation: Wang Yongpeng, Luo Jia, Bai Jian, Liang Yiyong. Analysis on mirrors installation error of high-accuracy long focal length measurement system[J]. Infrared and Laser Engineering, 2014, 43(2): 562-568.

Analysis on mirrors installation error of high-accuracy long focal length measurement system

  • Received Date: 2013-06-20
  • Rev Recd Date: 2013-07-23
  • Publish Date: 2014-02-25
  • As to minimize size of the measurement system of large size and ultra-long focal length lens, two mirrors are used to change light path. In this case, installation error of the two mirrors added may be a large obstacle to accurate measurement of ultra-long focal length lens. For the sake of analyzing how installation error of two mirrors infect the angle of Moir stripes on receiver, Moir stripes are understood as parallel lines which composed of point light source with certain light-path vector. This approach proposed uses the calculation formula from mirror deflection angle to the reflector unit normal vector, and the matrix form of the law of reflection, to calculate the relationship matrix from vector of incident light to vector of exit light. Based on unit normal vector of two mirrors, incident light-path vector, exit light-path vector, and analytic geometry, equation of line on which image of point light source place can be presented, so we can get the angle of Moir stripes on receiver and so is the angle error caused by installation error of the two mirrors added into light path. In addition, the angle error of Moir stripes is calculated theoretically in 49 different situations of small mirrors deflection smaller than 1 degree. The results indicate that the installation error of the two mirrors should be taken into consideration. A new method by using autocollimator to adjust the installation error of the two mirrors is proposed, installation error of the two mirrors can be controlled to lower than 1 through this method. Moir stripes angle error should be better than(10-4) order of magnitude in this situation. Experimental results show that Moir stripes angle measurement error is 0.005 degree, which fully illustrates the effect of mirrors adjustment when this system is used for the measurement of ultra-long focal length.
  • [1]
    [2] Jin Xiaorong, Zhang Jinchun, Bai Jian, et al. Calibration method for high-accuracy measurement of long focal length with Talbot interferometry[J]. Applied Optics, 2012, 51(13): 2407-2413. (in Chinese)
    [3]
    [4] Zhao W, Sun R, Qiu L, et al. Laser differential confocal ultra-long focal length measurement[J]. Optics Express, 2009, 17(22): 20051-20062.
    [5]
    [6] Sun Chen, Shen Yibing, Bai Jian, et al. The precision limit analysis of long focal length testing based on talbot effect of ronchi grating[J]. Acta Photonica Sinica, 2004, 33(10): 1214-1217. (in Chinese)
    [7] Xu Chuangang, Song Liquan. Design and realization of infrared complicated scene simulation system[J]. Infrared and Laser Engineering, 2005, 34(2): 241-242, 252. (in Chinese)
    [8] 孙琛, 沈亦兵, 白剑, 等. Ronchi光栅Talbot效应长焦距测量的准确度极限研究[J]. 光子学报, 2004, 33(10): 1214-1217.
    [9]
    [10] Wu Yaping, Zhang Tianxu. Simulation of infrared image and the simulation software[J]. Infrared and Laser Engineering, 2000, 29(4): 1-3. (in Chinese)
    [11]
    [12] Shi Yali, Gao Yunguo, Deng Weijie. Model for computer-aided alignment of reflective optical system[J]. Laser Infrared, 2009, 39(4): 427-430. (in Chinese)
    [13] Faugras O, Luong Q, Maybank S. Camera selfcalibration: theory and experiments[C]//ECCV, 1992: 321-334.
    [14] 徐传刚, 宋利权. 红外复杂场景仿真系统的设计与实现. 红外与激光工程, 2005, 34(2): 241-242, 252.
    [15] Li Xiaotong, Cen Zhaofeng. Geometrical Optics, Aberrations and Optical Design[M]. Hangzhou: Zhejiang University Press, 2003: 6-7. (in Chinese)
    [16]
    [17]
    [18] Yang Guoguang. Modern Optical Measurement Technology[M]. Hangzhou: Zhejiang University Press, 1997: 85-86. (in Chinese)
    [19] 吴亚平, 张天序. 红外图像的计算机仿真及仿真软件[J]. 红外与激光工程, 2000, 29(4): 1-3.
    [20] Ou Jiaming, Wang Ruili, Zhang Shulian, et al. Three forms of expression about reflection law[J]. Journal of Yunnan Normal University, 2000, 20(1): 57-61. (in Chinese)
    [21]
    [22]
    [23] 史亚莉, 高云国, 邓伟杰. 反射光路的计算机辅助装调模型[J]. 激光与红外, 2009, 39(4): 427-430.
    [24]
    [25]
    [26]
    [27] 李晓彤, 岑兆丰. 几何光学相差光学设计[M]. 杭州: 浙江大学出版社, 2003: 6-7.
    [28]
    [29]
    [30] 杨国光. 近代光学测试技术[M]. 杭州: 浙江大学出版社, 1997: 85-86.
    [31]
    [32]
    [33] 欧家鸣, 王瑞丽, 张书练, 等. 反射定律的三种表达形式[J]. 云南师范大学学报, 2000, 20(1): 57-61.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(364) PDF downloads(183) Cited by()

Related
Proportional views

Analysis on mirrors installation error of high-accuracy long focal length measurement system

  • 1. State Key Laboratory of Modern Optical Instrumentation,Zhejiang University,Hangzhou 310027,China

Abstract: As to minimize size of the measurement system of large size and ultra-long focal length lens, two mirrors are used to change light path. In this case, installation error of the two mirrors added may be a large obstacle to accurate measurement of ultra-long focal length lens. For the sake of analyzing how installation error of two mirrors infect the angle of Moir stripes on receiver, Moir stripes are understood as parallel lines which composed of point light source with certain light-path vector. This approach proposed uses the calculation formula from mirror deflection angle to the reflector unit normal vector, and the matrix form of the law of reflection, to calculate the relationship matrix from vector of incident light to vector of exit light. Based on unit normal vector of two mirrors, incident light-path vector, exit light-path vector, and analytic geometry, equation of line on which image of point light source place can be presented, so we can get the angle of Moir stripes on receiver and so is the angle error caused by installation error of the two mirrors added into light path. In addition, the angle error of Moir stripes is calculated theoretically in 49 different situations of small mirrors deflection smaller than 1 degree. The results indicate that the installation error of the two mirrors should be taken into consideration. A new method by using autocollimator to adjust the installation error of the two mirrors is proposed, installation error of the two mirrors can be controlled to lower than 1 through this method. Moir stripes angle error should be better than(10-4) order of magnitude in this situation. Experimental results show that Moir stripes angle measurement error is 0.005 degree, which fully illustrates the effect of mirrors adjustment when this system is used for the measurement of ultra-long focal length.

Reference (33)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return