Zhu Yingfeng, Han Fuzhong, Li Dongsheng, Huang Yibin, Mao Jingxiang. MW 320×256 IRFPA detector under rapid cooling down[J]. Infrared and Laser Engineering, 2014, 43(4): 1032-1036.
Citation: Zhu Yingfeng, Han Fuzhong, Li Dongsheng, Huang Yibin, Mao Jingxiang. MW 320×256 IRFPA detector under rapid cooling down[J]. Infrared and Laser Engineering, 2014, 43(4): 1032-1036.

MW 320×256 IRFPA detector under rapid cooling down

  • Received Date: 2013-08-05
  • Rev Recd Date: 2013-09-03
  • Publish Date: 2014-04-25
  • The rapid cooling down stress deformation is one of the key factors for the reliability of FPA. Combined with chemical corrosion, a mechanical grinding method was studied in this paper to reduce the thickness of FPA chip, and therefore improving its flexibility. The amount of bad pixel and crack owing to pixel damage generated by stress transfer was reduced obviously in the thinned chips. The cold head expansion matched to decrease the cool down stress of the chip was also optimized, without increasing the structural components of the Dewar cold head. After verified by reliability testing, the long-term reliability and stability of the 320256 IRFPA detector under a rapid cooling startup was improved obviously by these optimizations.
  • [1]
    [2] Tao Yu, Zhang Zhiquan. Military application of staring infrared focal plane subassembly [J]. Infrared and Laser Engineering, 2001, 30: 70-73. (in Chinese)
    [3]
    [4] Xavier B, Philippe T. IR detectors design and approach for tactical applications with high reliability without maintenance[C]//SPIE, 2008: 69400.
    [5]
    [6] Marianne M, Xavier B, Philippe T. IR detector dewar and assemblies for stringent environmental conditions [C]//SPIE, 2007: 6542-6585.
    [7] Gong Haimei, Zhang Yani, Zhu Sangen, et al. Study of reliable packaging for IRFPA dector [J]. Journal of Infrared and Millimeter Waves, 2009, 28(2): 85-89. (in Chinese)
    [8]
    [9]
    [10] Fang Guangyu, Gong Haimei, Li Yanjin, et al. Temperature-cycling-reliability of IRFPA device [J]. Infrared and Laser Engineering, 2010, 8: 607-610. (in Chinese)
    [11]
    [12] Rolin K A. Infrared focal plane array storage life assessment by accelerated aging[J]. Qualitity and Reliability Engineering International, 1998, 14(6): 425-432.
    [13] Rogalski A, Chrzanowski K. Infrared devices and techniques[J]. Pto-Electronics Review, 2002, 10(2): 111-136.
    [14]
    [15]
    [16] Li Yanjin, He Li, Yang Jianrong, et al. Study on thermal mismatch stress of HgCdTe infrared focal plane array [J]. Journal of Infrared and Millimeter Waves, 2008, 27 (6): 409-412. (in Chinese)
    [17] Li Yanjin. Method of reducing thermal mismatch stress in infrared focal plane assembly [J]. Science and Technology Review, 2011, 29(8): 27-30. (in Chinese)
    [18]
    [19]
    [20] Qiu Hong, Cao Lingxia. InSb IRFPA back lpping technology[J]. Laser and Infrared, 2001, 31(5): 286-287. (in Chinese)
    [21]
    [22] Xavier B, Philippe T. IR detectors life cycle cost and reliability optimization for tactical applications [C]//SPIE, 2006: 63950D.
    [23] Brenire X, Manissadjian A, Vuillermet M, et al.Reliability optimization for IR detectors with compact cryo-coolers[C]// SPIE, 2005: 187.
    [24]
    [25]
    [26] Tian Liping, Zhu Yingfeng, Liu Xiangyun, et al. Back-thining on reliability influence for MW 320256 MCT IRFPA [J]. Infrared Technology, 2013, (10): 629-631. (in Chinese)
    [27] Deng Gang, Han Hengli, Zhong Sicheng. Backside-illuminated charge-coupled devices (CCDS) thinning technology [J]. Electronoic Science and Technology, 2014, 27(2): 68-70. (in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(320) PDF downloads(200) Cited by()

Related
Proportional views

MW 320×256 IRFPA detector under rapid cooling down

  • 1. Kunming Institute of Physics,Kunming 650223,China

Abstract: The rapid cooling down stress deformation is one of the key factors for the reliability of FPA. Combined with chemical corrosion, a mechanical grinding method was studied in this paper to reduce the thickness of FPA chip, and therefore improving its flexibility. The amount of bad pixel and crack owing to pixel damage generated by stress transfer was reduced obviously in the thinned chips. The cold head expansion matched to decrease the cool down stress of the chip was also optimized, without increasing the structural components of the Dewar cold head. After verified by reliability testing, the long-term reliability and stability of the 320256 IRFPA detector under a rapid cooling startup was improved obviously by these optimizations.

Reference (27)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return